3.2.13. Removing the Safety Switch

Prerequisite condition:3.2.3/3.2.7/3.2.8
1. Disconnect the Fast-on tab terminals of the two cables connected to the safety
switch.
2. Remove two fixing screws from the safety switch and detach the safety switch.
Screw: +M3*12 F/Zn Bind: P-Tight P/N1021823 (mounting torque: 6.0 kg.cm = 5.2
lb.inch)
Caution:
When removing the Fast-on terminals, do not apply excessive force to the terminals
on the safety switch in the horizontal or vertical direction.
* The polarity of the cables is not significant; connect them to any terminals on the
safety switch.
REV.A
Fast-on tab
screws
Figure3- 27