2.15.5 Front Temperature Thermistor

This is the temperature detection thermistor installed on the side of the fan (attached
to the power supply unit). If the circumstances around the power supply unit become
the overheat condition by the abnormal fan or circuit condition, this thermistor shuts
off the power. The power shut off control is the same as the lamp house thermistor's
written in 2.15.3.
Front temperature Thermister
Figure 2-47 Front temperature thermistor
REV.A