Mains Electricity
Connection
Warning! This appliance must be
earthed.
We recommend that the appliance is
connected by a qualified electrician,
who is a member of the N.I.C.E.I.C. and
who will comply with the I.E.T. and local
regulations.
This appliance is intended to be
connected to fixed wiring but is also
suitable for connection to a 13A plug.
Any plug fitted to this appliance must
be BS 1363A type. Any plug fuse used
must be ASTA approved to BS 1362
type.
If installing this appliance to fixed wiring then it must be
connected by a double pole switch, having a contact separation
of at least 3mm in all poles. The switch must be positioned no
further than 2m from the appliance.
Please note:
The mains cable must only be replaced by a qualified electrician
or service engineer and must be of equivalent or better rating (i.e.
1.5mm 2 , HO5VV-F).
20
L
N
Live L: BN - brown
Neutral N: BU - blue
Earth PE: GNYE -green/yellow
Fig. 13