Sonoscape A6T User Manual

Sonoscape A6T User Manual

Portable ultrasonic diagnostic system
Table of Contents

Advertisement

1
System Safety ......................................................................1-1
1.1
Safety Overview .................................................................... 1-1
1.2
Warning Signs ....................................................................... 1-3
1.3
Biological safety .................................................................... 1-4
1.4
Ultrasound Safety.................................................................. 1-4
1.5
Operating Environment ......................................................... 1-4
1.6
Transport and storage ........................................................... 1-5
1.7
Electrical Requirements......................................................... 1-5
1.8
Electrical Safety Classification............................................... 1-6
2
System Description .............................................................2-1
2.1
General.................................................................................. 2-1
2.2
Application............................................................................. 2-1
2.3
Contraindication .................................................................... 2-2
2.4
System Configuration ............................................................ 2-2
2.4.1
Configuration.................................................................. 2-2
2.4.2
Standard Configuration................................................... 2-3
2.4.3
Optional Accessories...................................................... 2-3
2.4.4
Optional Peripherals....................................................... 2-3
2.5
Technical Specifications ........................................................ 2-5
2.6
System Principle.................................................................... 2-8
3
System Operation ................................................................3-1
3.1
Operation Notice ................................................................... 3-1
3.2
Transducer Connection ......................................................... 3-1
3.3
System Power ON/OFF......................................................... 3-2
3.4
General Operation................................................................. 3-3
3.4.1
Keyboard Operation ....................................................... 3-3
3.4.2
User Interface................................................................. 3-6
3.4.3
System Setting ............................................................... 3-7
3.4.3.1
3.4.3.2
3.4.3.3
3.4.3.4
3.4.3.5
3.4.4
Patient Information ....................................................... 3-17
3.4.3.6
3.4.3.7
3.4.5
BodyMark ..................................................................... 3-23
A6T/A6/A5 Portable Ultrasonic Diagnostic System

TABLE OF CONTENTS

General Setting ................................................ 3-8
Dicom Setting................................................... 3-9
Formula Select............................................... 3-10
Formula Define .............................................. 3-12
Comment Setting ........................................... 3-14
Disk Management .......................................... 3-18
LCD Setting.................................................... 3-22
4701-0040-01A
I

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A6T and is the answer not in the manual?

Questions and answers

beheton todoegnon
April 17, 2025

on arrive pas avoir les mesures

1 comments:
Mr. Anderson
May 9, 2025

To obtain measurements on the Sonoscape A6T:

1. In B mode, freeze the image.
2. Press the 【Calc】 key to open the Meas & Calc menu.
3. Use the trackball to select “Cardiac” and press 【SET】.
4. Select “LV” and press 【SET】.
5. Select “Bullet” and press 【SET】 to enter measurement mode.
6. Measure LVAMd using the “Area/Cir measurement (Ellipse)” method.
7. Measure LVLd using the “Distance Measurement” method.
8. Unfreeze the image, rescan, and freeze again to repeat measurements if needed.

The system calculates EDV, ESV, SV, CO, EF, SI, and CI using the measured values.