Operate the Uponor Smatrix Move/Move PLUS

CZ
controller
DE
8.1

Principle of operation

DK
Uponor Smatrix Move
The controller calculates the supply temperature
using the outdoor temperature and a heating curve.
EE
The calculated supply temperature is compared to
the measured supply temperature. If the measured
temperature differs from the calculated, the controller
ES
adjusts the flow through the mixer valve to raise or
lower the supply temperature.
FI
Uponor Smatrix Move PLUS
The controller calculates the supply temperature
using the outdoor temperature and a heating curve.
FR
The calculated supply temperature is compared to
the measured supply temperature. If the measured
temperature differs from the calculated, the controller
HR
adjusts the flow through the mixer valve to raise or
lower the supply temperature.
If a thermostat is present in the system, it is also used
HU
to further adjust the flow to the reference room and to
reach the setpoint quicker.
IT
As soon as the temperature measured at the thermostat
is lower (heating mode) or higher (cooling mode) than
the setpoint temperature, a demand to change the room
LT
temperature is created and sent to the controller. The
controller will open the actuator according to current
operating mode and other settings. Once the set
LV
temperature is reached, the actuator closes.
NL
NO
PL
PT
RO
RU
SE
SK
3 8
8.2
The illustration below shows parts of the controller.
Item
A
B
C
D
U P O N O R S M AT R I X M O V E / M O V E P L U S · I N S TA L L AT I O N A N D O P E R AT I O N M A N U A L

Controller layout

P
AUTO
0h
2
4
6
8
10
12
14
16
18
20
22
24
B
C C
B
Description
Display
Navigation buttons
Used for selecting mode, parameter, and
scheduling program
The - and + buttons are used to:
Adjust setpoint temperature
Modify parameters in the settings menus
The OK button is used to:
Toggle between current status data, and
values of available sensors connected to the
controller
Enter and exit the settings menu
Confirm a setting
A
D