Summary of Contents for Uponor SmatrixMove

  • Page 1 Uponor Smatrix Move/Move PLUS U K I N S TA L L AT I O N A N D O P E R AT I O N M A N U A L 03 | 2015...
  • Page 2: Table Of Contents

    System overview ............5 10.8 Change control mode ..........62 Example of a system ..........5 10.9 Settings ..............62 Uponor Smatrix Move/Move PLUS components ..6 10.10 Replace batteries ............66 Accessories .............10 10.11 Factory reset ............66 Functions..............10 Maintenance ............67 Install Uponor Smatrix Move/Move PLUS ..12 11.1...
  • Page 3: Copyright And Disclaimer

    Modification or use of any of the contents of the or obligation. The manual is provided “as is” without manual for any other purpose is a violation of Uponor’s warranties of any kind, either expressed or implied. The copyright, trademark and other proprietary rights.
  • Page 4: Preface

    This product should not be mixed with other commercial Power wastes of disposal. Warning! The Uponor system uses 230 V AC, 50 Hz power. In case of emergency, immediately disconnect the power. Technical constraints Caution!
  • Page 5: Uponor Smatrix Move/Move Plus

    Uponor Smatrix Move Sensor Supply/Return S-152 (return sensor S-152) Uponor Smatrix Move PLUS Uponor Smatrix Move Sensor Supply/Return S-152 Uponor Smatrix Move PLUS is used to control a heating (supply sensor S-152) and cooling system. It consists of a controller with an Circulation pump...
  • Page 6: Uponor Smatrix Move/Move Plus Components

    Uponor Smatrix Move PLUS Uponor Smatrix Move/Move PLUS The illustration below shows Uponor Smatrix Move components PLUS with several installation options and a thermostat. Pos. Uponor designation Description Uponor Smatrix Move Controller Controller H X-157 Uponor Smatrix Move Controller PLUS Controller H/C...
  • Page 7 Uponor Smatrix Move Controller H X-157 • Lower indoor temperature with night set back (ECO mode). The Uponor Smatrix Move Controller H X-157 uses an outdoor temperature sensor, a supply temperature • System integration with an Uponor Smatrix Wave/ sensor, an optional return temperature sensor, and Wave PLUS/Space/Space PLUS system.
  • Page 8 The illustration below shows the thermostat and its controller through radio transmissions. It is possible components. to mix a maximum of two different types of Uponor Smatrix Wave thermostats in the same installation. One of these thermostats can only function as a wireless connection point for the outdoor temperature sensor.
  • Page 9 Components of the thermostat: The illustration below shows the thermostat and its Item Description components. Uponor Smatrix Wave PLUS Thermostat D+RH T-167 Wall bracket Stand Batteries (AAA 1.5 V) Mounting material Connection terminal Uponor Smatrix Wave Thermostat Prog.+RH T-168...
  • Page 10: Accessories

    Accessories adjusts the flow through the mixer valve to raise or lower the supply temperature. Uponor offers a wide variety of accessories for use with the standard portfolio. If a thermostat is present in the system, it is also used to further adjust the flow to the reference room and to reach the setpoint quicker.
  • Page 11 See separate documentation on how to register the (Move PLUS only) thermostat to a Wave/Wave PLUS/Space/Space PLUS Uponor uses an Offset temperature to adjust the system. setpoints when switching between heating and cooling. This improves the performance of the system and reduces the need of manual setpoint adjustments when switching between heating and cooling.
  • Page 12: Install Uponor Smatrix Move/Move Plus

    • Study the wiring diagram in the end of this manual. Uponor Smatrix Move PLUS To determine where to best place the Uponor Smatrix Uponor recommends following the process described Move/Move PLUS components, follow these guidelines: below to guarantee the best possible installation results.
  • Page 13: Installation Examples

    The calculated supply temperature is compared to • Basic heating system, with Uponor Smatrix Move/ the measured supply temperature. If the measured Move PLUS temperature differs from the calculated, the controller adjusts the flow through the mixer valve to raise or •...
  • Page 14 Basic heating system Example specific electrical connections Move PLUS Move PLUS • The circulation pump is connected to the terminal labelled P1. • The mixer valve actuator is connected to the Move terminal labelled ACTUATOR. See section 5.4 Connect components to controller for more information.
  • Page 15 Heating and cooling system An optional switchover valve (option 2) can be used to divert the supply between the heating and cooling Move PLUS Move PLUS sources. An optional return temperature sensor (option 3), is Move in a Move system connected the controller to speed up the reaction of the system.
  • Page 16 Heating system together with DHWT and of the second circulation pump, supplying the panel panel heater heater, can be controlled by an optional extra wireless thermostat (Move PLUS only). Move PLUS Move PLUS An optional return temperature sensor (option 3), is in a Move system connected the controller to speed up the reaction of the system.
  • Page 17 Warning! There is 230 V (5 A) power in the controller when connected to the mains. The Uponor Smatrix Move PLUS controller can be integrated with an Uponor Smatrix Wave/Wave PLUS system to enhance the capabilities of a full climate system.
  • Page 18 • Set parameter 4 – Type of system to Act if the and hot water, and an Uponor pump group (EPG) external 3-way valve and circulation pump is supplies the system with free cooling. For best per- installed.
  • Page 19: Install Uponor Smatrix Move/Move Plus Controller

    N O T E ! N O T E ! Only 230 V Uponor actuators are compatible The antenna must be installed vertically for with the controller. best coverage. U P O N O R S M AT R I X M O V E / M O V E P L U S · I N S TA L L AT I O N A N D O P E R AT I O N M A N U A L...
  • Page 20: Connect Components To Controller

    Connect the antenna cable Connect components to controller The illustration below shows how to connect the Prior to connecting a component, study the wiring antenna to the controller. diagram, in the end of the manual, or the printed circuit board in the controller, to locate the connector positions.
  • Page 21 N O T E ! See the documentation from the circulation pump supplier as well as relevant Uponor wiring diagrams before connecting the pump. Warning! There is 230 V (5 A) power in the controller to supply circulation pump 1 when the controller is connected to the mains.
  • Page 22 See the documentation from the circulation heat source. pump supplier as well as relevant Uponor Alternatively, the boiler relay can be used to send wiring diagrams before connecting the pump.
  • Page 23 The outdoor sensor is wired to a thermostat, which heating/cooling input. is communicating with the controller by radio link. See section 6 Install Uponor Smatrix Wave/Wave See section 8.5 System parameter settings for more PLUS thermostats and sensors for more information.
  • Page 24 Connect supply temperature sensor to Connect return temperature sensor to controller controller (optional) A supply temperature sensor can be connected to the A return temperature sensor can be connected to the controller. controller. The illustration below shows the connection of a supply If a return temperature sensor is installed, it is possible temperature sensor to the controller.
  • Page 25 Connect heating/cooling switch to Connect circulation pump start signal controller (optional) to controller (optional) A heating/cooling switch can be connected to one of A circulation pump start signal can be connected to one the two wired input terminals on the controller of the two wired input terminals on the controller.
  • Page 26: Connect The Controller To Ac Power

    The registration process is completed when connected to the mains. while setting system parameters. Warning! See section 6 Install Uponor Smatrix Wave/Wave PLUS thermostats and sensors for installation of thermostats. Electrical installation and service behind secured 230 V AC covers must be carried...
  • Page 27: Install Uponor Smatrix Wave/Wave Plus Thermostats And Sensors

    • Room temperature Caution! • Room and floor temperature (floor temperature Do not attempt to connect Uponor Smatrix display only) Base thermostats to the controller. They are not suited for each other, and they may get • Room and outdoor temperature damaged.
  • Page 28: Connect External Sensor To Thermostat (Optional)

    N O T E ! to the use of the sensor and thermostat. For accurate temperature: attach the outdoor See section 10 Operate Uponor Smatrix Wave/Wave sensor to the north side of the building where PLUS digital thermostats for more information.
  • Page 29: Attach A Thermostat To The Wall

    Attach a thermostat to the wall Using adhesive strip The illustration below shows how to attach the The thermostats are delivered in kits including screws, thermostat to the wall using an adhesive strip and a wall wall plugs, and a wall bracket. Presenting several bracket.
  • Page 30: First Startup Of Digital Thermostats

    3. Set 12 h or 24 h display of time. At first startup, before registering, the thermostat requires some basic settings. See section 12 Operate Uponor Smatrix Wave/Wave PLUS digital thermostats for more information. Software version 4. Set day of the week (1 = Monday, 7 = Sunday).
  • Page 31: First Setup Of Digital Thermostat

    First setup of digital thermostat Setpoint temperature The thermostat is delivered with a default setpoint of Select thermostat control mode 21 °C. If an external sensor is connected to the thermostat, The illustration below shows how to adjust the a control mode must be selected to accommodate the thermostat temperature setpoint.
  • Page 32: Register A Thermostat To The Controller

    The DIP switches in public thermostat T-163 must be set before the thermostat is registered. Caution! Do not attempt to connect Uponor Smatrix Base thermostats to the controller. They are not suited for each other, and they may get damaged.
  • Page 33 6. Use buttons < or > to locate parameter 8 (trF1) Thermostat T-163 – Wireless thermostat 1 configuration. 8.1 Gently press and hold the registration button 7. Use buttons - or + to change parameter settings to on the thermostat, release when the LED starts flashing green (located in the hole above the INI.
  • Page 34 6.10 Register a wireless outdoor sensor to the controller 10 s AUTO Caution! The DIP switches in public thermostat T-163 must be set before the thermostat is registered. N O T E ! If the outdoor sensor is placed to far away from the reference room, a separate thermostat can be used to register the outdoor sensor.
  • Page 35 8. Thermostat T-166, T-167 and T-168 Thermostat T-163 8.1 Press and hold the OK button on the 8.1 Make sure the DIP switch is set correctly. thermostat for about 5 seconds to enter the 8.2 Gently press and hold the registration button settings menu.
  • Page 36: Register A Wired Outdoor Sensor

    6.11 Register a wired outdoor sensor To register a wired outdoor sensor to the controller: 1. Press and hold the OK button on the controller for about 10 seconds to enter the system parameters menu. 2. The settings icon is displayed in the top left hand corner of the display, and the text Hot type, Cld 10 s type, or rEv type (depending of current operating...
  • Page 37: Finishing Installation

    Finishing installation Uponor Smatrix Move Uponor Smatrix Move PLUS Make a complete check up of the installation: 1. Close the cover of the controller. 2. Set the controller to the defined operating settings. 3. Print and fill in the “Installation report” located at the end of the manual.
  • Page 38: Operate The Uponor Smatrix Move/Move Plus

    Operate the Uponor Smatrix Move/Move PLUS controller Principle of operation Controller layout The illustration below shows parts of the controller. Uponor Smatrix Move The controller calculates the supply temperature using the outdoor temperature and a heating curve. The calculated supply temperature is compared to AUTO the measured supply temperature.
  • Page 39: Display Layout

    Display layout Pos. Icon Description Temperature The figure below shows all possible symbols and characters that can be shown on the display: Relative humidity H I J K L Digital clock Auto Parameter name in settings menu 1 2 3 4 5 6 7 Indicator showing AM or PM when the thermostat is set to 12 h mode 24 hour mode (no symbol shown)
  • Page 40 Operating modes Systems with a supply temperature sensor, an outdoor temperature sensor and a thermostat: Use buttons < or > to change operating mode. A box shows which mode has been selected. • The supply temperature is calculated using the outdoor temperature with the heating and cooling Available operating modes and settings in run mode are curve (System parameters >...
  • Page 41: Comfort Mode

    Comfort mode Change offset temperature when in another operating mode: In this mode the system will run in constant Comfort mode. To exit Comfort mode, use buttons < or > to 1. Use buttons < or > to move the marker to the change operating mode.
  • Page 42: Automatic Mode

    Automatic mode 6. Press the OK button to confirm, the days of the week starts flashing. In this mode, the system switches automatically between Comfort and ECO mode using the preset 1 2 3 4 5 6 7 or user defined scheduling programs available in the Scheduled programs menu.
  • Page 43 ECO mode 3. Press the OK button or wait about 7 seconds until the new setting is confirmed. In this mode the system will run in constant ECO mode. To exit ECO mode, use buttons < or > to change Current supply and outdoor temperatures is operating mode.
  • Page 44 Heating/cooling mode Program P3: In this mode the system can be switched between heating or cooling. N O T E ! This mode requires system parameter 0 – Type of installation being set to rEv. N O T E ! This mode is hidden if a wireless thermostat is registered to the controller, or if system parameters 11 or 12 is set to HC.
  • Page 45 Program P7: 4. Press the OK button to confirm selection of user defined scheduled program (U1 – U4). The digital clock starts flashing and day 1 is marked. AUTO 1 2 3 4 5 6 7 5. Use buttons < or > to select where during the day to start programming.
  • Page 46: System Parameter Settings

    System parameter settings Menu Display Description BGAP Boost function, if the difference In this menu, settings regarding the operation of the between the supply and return controller is set. temperature is too high N O T E ! trF1 Wireless thermostat 1 configuration Some system parameter settings are only trF2 Wireless thermostat 2 configuration...
  • Page 47 To change this setting: 2 – Maximum supply temperature (heating) 1. Use buttons - or + to toggle between Hot, CLd and rEv. Hot (Default) Heating system only CLd Cooling system only Heating and cooling system 2. Press OK to confirm the change and return to the system parameter settings.
  • Page 48 1 – Cooling curve 3 – Minimum supply temperature (cooling) Set the cooling curve of the system. Set a minimum supply temperature limitation, while in The cooling curve is used to calculate the supply cooling mode. temperature to the cooling system, while in cooling mode.
  • Page 49 If the difference between the supply and return Caution! temperature is higher than the set value, the function Do not attempt to connect Uponor Smatrix activates. Base thermostats to the controller. They are not suited for each other, and they may get When activated, the boost function increases (heating damaged.
  • Page 50 8 – Wireless thermostat 1 configuration 9 – Wireless thermostat 2 configuration This parameter is only available if parameter 5 – This parameter is only available if parameter 5 – Thermostat selection is set to rF (Move PLUS only). Thermostat selection is set to rF, and parameter 4 – Type of system is set to 2P.1 or 2P.2.
  • Page 51 10 – Supply temperature compensation 11 – Wired input 1 selection This parameter is only available if parameter 5 – Set if optional wired input 1 (terminal block ln1) is used, Thermostat selection is set to rF, and a thermostat is and which function it has.
  • Page 52 N O T E ! If the Move PLUS system is integrated to an Phase signal (closed circuit) = Circulation Uponor Smatrix Wave/Wave PLUS system, pump ON energy saving can be ensured by using the 2. Press OK to confirm the change and return to the pump logic of an electric connecting box, to system parameter settings.
  • Page 53 14 – Outdoor temperature, fixed 16 – Display unit This parameter is only available if parameter 13 – Select the temperature display unit used by the Outdoor sensor selection is set to no. controller. Set a fixed outdoor temperature that is used to calculate To change this setting: the supply temperature, when no outdoor sensor is 1.
  • Page 54 18 – Valve and pump exercise 20 – Forced control Select if the valve and pump exercise function is active. Select this parameter to forced control of the actuator. The function is activated at noon (12:00) if the valve N O T E ! and pump has not been operated for a period of If a button is pressed, the actuator stops for 24 hours.
  • Page 55 21 – Floor/Screed preheating program 22 – Floor/Screed drying program DIN 1264-4 Select this function to activate a floor/screed drying Select this function to activate a floor/screed program. The drying program is used to prevent damage preheating program. The preheating program is used of newly built underfloor heating systems in cold to prevent damage of newly built underfloor heating houses.
  • Page 56 23 – Factory reset Select this function to reset all controller parameters to default values. N O T E ! This function resets all controller parameters to default values. This includes registration data for wireless thermostats and sensors, and user customised scheduling programs.
  • Page 57: Ru 9 Operate Uponor Smatrix Wave Analogue

    Two types of thermostats, both analogue and digital, Adjust temperature can be used in an Uponor Smatrix Move PLUS system. The temperature is changed by adjusting the setpoint on the thermostat to a value between 5 and 35 ˚C.
  • Page 58: Factory Reset

    Factory reset Factory reset sets all parameter values to default settings. N O T E ! Do not factory reset the thermostat if not absolutely needed. N O T E ! A factory reset removes the registration data from the thermostat. To factory reset an analogue thermostat: 1.
  • Page 59: Operate Uponor Smatrix Wave/Wave Plus Digital Thermostats

    Two types of thermostats, both analogue and digital, 10.2 Display layout can be used in an Uponor Smatrix Move PLUS system. The figure below shows all possible symbols and The digital thermostats have a display relaying characters that can be shown on the display: information to the user and buttons for control.
  • Page 60: Operating Buttons

    Pos. Icon Description Pos. Icon Description T-168 only Low battery indicator Time selected or scheduled hour indicators, for Comfort mode, between 0:00 and 24:00 Half = 30 minutes Temperature unit, shown when the character group A shows a temperature Full = 1 hour 10.3 Operating buttons Communication indicator The figure below shows buttons used to operate the...
  • Page 61: Adjust Temperature

    Set time and date (T-168 only) 7. Set year. When starting the thermostat for the first time, after a factory reset, or after it has been left without batteries too long, the software requires the time and date to be set.
  • Page 62: Control Mode

    10.7 Control mode 2. The settings icon and menu numbers are displayed in the top right corner of the display. The thermostat has four different control modes, set in 3. Use buttons - or + to change the numbers to 04 the settings menu.
  • Page 63 00 Program (T-168 only) Program P5: In this menu, one of seven different scheduling programs for Comfort/ECO mode can be set. Program 1 to 6 is pre-programmed and the 7th is user programmable. Program Off (default): Program P1: Program P6: Program P2: To change this setting: 1.
  • Page 64 2.1.4 When the day is fully programmed, the 03 ECO mode setback temperature software exits to the settings menu. In this menu the setback temperature for whenever the channel is in ECO mode is set. 2.1.5 Repeat from step 1 if more days are to be The setting adjusts the current setpoint with the set programmed.
  • Page 65 05 High floor temperature limitation 07 Cooling allowed In this menu a limit on the maximum allowable floor In this menu it is set whether cooling is allowed in the temperature is set. Limitations does not affect the system or not. operation of the Move PLUS controller, when not To change this setting: integrated to a Wave/Wave PLUS/Space/Space PLUS...
  • Page 66: Replace Batteries

    10 Time and date (T-168 only) 10.11 Factory reset In this menu time and date is set. This setting is required Factory reset sets all parameter values to default to utilise scheduling programs for this thermostat. settings. Use buttons - or + to change the value. Press the OK N O T E ! button to set the value and move to the next editable Do not factory reset the thermostat if not...
  • Page 67: Maintenance

    The valve and pump exercise function is enabled from the factory and can be disabled in the system parameters. See section 8 Operate the Uponor Smatrix Move/Move PLUS controller for more information. The function is activated at noon (12:00) if the valve and pump has not been operated for a period of 24 hours.
  • Page 68: Troubleshooting

    12 Troubleshooting The table below shows problems and alarms that can occur with Uponor Smatrix Move/Move PLUS and describes solutions. A common cause of a problem though may be due to wrongly installed loops or mixed up thermostats. Alarms are indicated by a flashing display and error messages on the display.
  • Page 69: Troubleshooting After Installation

    Probable cause Problem Indication Solutions Disturbing noise Pump exercise function active from pump at same time and day of week 12.1 Troubleshooting after installation Probable cause Problem Indication Solutions The system does The display is not illuminated There is no AC power to the controller 1.
  • Page 70: Analogue Thermostat T-163, Alarms/Problems

    12.3 Analogue thermostat T-163, alarms/problems An alarm is sent when more than 1 hour have elapsed since the controller received the last radio signal from the thermostat. The table below lists problems that can occur in the public thermostat T-163. Probable cause Indication Solutions...
  • Page 71: Technical Data

    13 Technical data 13.1 Technical data General IP30 (IP: degree of inaccessibility to active parts of the product and degree of water) Max. ambient RH (relative humidity) 85% at 20 °C Thermostat (Move PLUS only) CE marking Low voltage tests EN 60730-1* and EN 60730-2-9*** EMC (electromagnetic compatibility requirements) tests EN 60730-1 and EN 301-489-3...
  • Page 72: Technical Specifications

    13.2 Technical specifications Cables Standard cable length Maximum cable length Wire gauge Cable from controller to antenna 0.30 m 10 m Controller: Plug connector Antenna: Plug connector Cable from controller to actuator 0.75 m 20 m Controller: 0.2 mm² to 1.5 mm² External sensor cable to thermostat 0.6 mm²...
  • Page 73: Controller Wiring Diagram

    13.4 Controller wiring diagram PUMP P1 ACTUATOR 230 V SENSORS POWER 230 V AC 230 V 50 Hz 50 Hz OUTSIDE * WATER RETURN ***** 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz WATER IN In1/In2 *** In1/In2 *** In1/In2 ** PUMP P2 **...
  • Page 74: Dimensions

    13.6 Dimensions Controller 53 mm 51 mm 86 mm 30 mm 43 mm Controller antenna 23 mm Thermostats 80 mm T-166 60 mm 26,5 mm T-167 T-168 80 mm T-163 60 mm 26,5 mm U P O N O R S M AT R I X M O V E / M O V E P L U S · I N S TA L L AT I O N A N D O P E R AT I O N M A N U A L...
  • Page 75: Installation Report

    Heating system or boiler Supply sensor thermostat (Move PLUS only) Return sensor (optional, Chiller Circulation pump 1 Move only) Integration with Uponor Integration with Uponor Smatrix Wave/Wave PLUS Smatrix Space/Space PLUS Circulation pump 2 (optional) system (Move PLUS only) system (Move PLUS only)
  • Page 76 Uponor Ltd www.uponor.co.uk Uponor reserves the right to make changes, without prior notification, to the specification of incorporated components in line with its policy of continuous improvement and development.