Installation - Indesit tcud93b Service Information

9 kg condenser electronic tumble dryers
Table of Contents

Advertisement

Indesit
Company
INTRODUCTION
The Condenser 'FUTURA' range was launched during 2011.
The Futura tumble dryers have redesigned Front Panels, Round Doors, Front Air Duct, Plinth, Worktop,
Water Container and a Fast Empty Water Bottle.
These new Tumble Dryers match the 'FUTURA' Washing Machines.

INSTALLATION

The dryer MUST be located away from gas stoves,
Minimum gap 10mm
hobs or heaters.
If the machine is located under a work surface, there
must be a 10 mm gap around any top or above the
dryer and a minimum 15 mm space along each side.
This is to ensure correct air circulation.
Minimum gaps
15mm
Draining the Machine into an Internal Drain
If the machine drains into an external drain, the water container will not need to be regularly emptied.
The height of the drain must be less than 1 metre from the bottom of the dryer.
Remove the existing hose from the position shown, Fig. 1. Fit a suitable length of hose (Part No.
C00279043) to the location shown in the photo (Fig. 2).
Confirm the hose is not squashed or kinked when the dryer is in its installed position.
Fig.1
Fig.3
Fig.2
Outlet Spigot
Remove this hose
New drain hose fitted
Service Manual UK
English
4 of 37