Indesit tcud93b Service Information page 29

9 kg condenser electronic tumble dryers
Table of Contents

Advertisement

Indesit
Company
FAULT
Cause
F12
No communication between
display module and control
module.
F13
Rear thermistor open or
short circuit.
F14
Upper element failure
F15
Upper element is on when it
should be off.
F16
Not used.
F17
Master Relay contacts
welded closed.
If testing for a Heater related fault, test on a Cotton High Heat setting or
Thermistor Resistance Readings:
Temperature
20°C
25°C
50°C
75°C
100°C
130°C
Service Manual UK
• Check connector J9 on module;
• Check wiring between module connector J9 and display;
• Check display connector;
• Replace module, display or wiring as required.
• Check security of module connector J4;
• Test from J4 connector pins 1 and 2 (approximately 500
Kohms);
• If open circuit, test thermistor and wiring between thermistor
and J4 to locate fault.
• Check security of module connector J4;
• Test between pins 4 and 5 on J4 (approximately 48 ohms);
• If open circuit, test upper element and the wiring between J4
and the heater.
• Check security of module connector J4;
• Check connector for signs of shorting due to moisture;
• Check heater elements and wiring;
• Replace module (F15 would normally be caused by a faulty
module).
• Replace module.
a Timed setting with High Heat enabled.
Resistance ( +/- 5%)
614 K Ohms
470 K Ohms
134 K Ohms
43.8 K Ohms
16.1 K Ohms
5.6 K Ohms