Fault Codes - Led Models - Indesit tcud93b Service Information

9 kg condenser electronic tumble dryers
Table of Contents

Advertisement

Indesit
Company
FAULT CODES - LED Console Models Only
When the machine's Electronics detect a fault:
> All of the Option and Start Led's will Flash Rapidly.
> The machine will continue with Drum Action only for a further 20 minutes.
> The Progress/Warning Lamps will illuminate (continually "ON") to display the relevant Fault Code
FAULT
F01
Motor triac in short circuit or Relay of
motor welded closed
F02
Blocked motor (fan blocked).
F03
Front NTC open or short circuit
F04
Pump working when should be off.
F05
Pump not working when should be on.
F06
Non used, active
F07
Lower element failure
F08
Static heater relay welded closed
F09
Error set-up file. EEPROM is not
programmed or not functioning
F10
Common of heater open, one shot open
F11
Pump open circuit.
F12
No communication between display
board and control board
F13
Rear NTC open or short circuit.
F14
Upper element failure
F15
Dynamic (PD) heater relay welded closed
F16
Not used, active
F17
Master relay welded closed
For additional Fault Code information see following pages.
Service Manual UK
CAUSE
27 of 37
LED 5
LED 4
LED 3
LED 2
LED 1
Option & Start LED's
will all flash together
when a fault code
is displayed
STATUS OF LEDs
LED COMBINATION
5
4
3
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
2
1
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON