Quicksilver 810 Arvor — System & Component Overview and Operation
Tank Storage
The LPG tank storage is located in the starboard walkthrough. The tanks must be firmly secured to the
boat with the tanks in a horizontal position. Do not relocate or reposition the tanks. Do not obstruct
access to the LPG tanks in any way. Make sure to keep valves on empty cylinders closed and
disconnected, and keep protective covers, caps or plugs in place. Only keep spare cylinders in
ventilated housings on open decks or in gas-tight lockers which are vented overboard and intended
for storing LPG tanks. Finally, do not use LPG cylinder housing for storage of any other equipment.
LPG Shutoff Valve
An inline fuel shutoff valve is located in the forward storage area in the galley. Always close fuel
supply line valves and cylinder valve when appliances are not in use. Also, remember to close all
valves before refueling and immediately in an emergency. Finally, be sure appliance valves are closed
before opening cylinder valve.
LPG Pipe & Hoses
Your LPG system consists of hoses connecting the LPG tank to the stove. The hoses in the LPG system
must be inspected regularly, at least annually, and replaced if any deterioration is found.
LPG System
LPG System
LPG working pressure: Butane = 28mbar, Propane = 37mbar
2kg LPG tank (not supplied)
Regulator (not supplied)
LPG tank hose
Tank to shutoff valve hose
Shutoff valve
Shutoff valve to stove hose
Stove