Technical Data - Webasto Thermo 90 ST B Installation Manual

Coolant heater
Hide thumbs Also See for Thermo 90 ST B:
Table of Contents

Advertisement

Thermo 90 ST

15. Technical Data

Except where limit values are specified, the technical data
refer to the usual heater tolerances of
ambient temperature of +20 °C (68 °F) and at the
nominal voltage and conditions.
15.1 Electrical Components:
The control module, motors for combustion air blower
and circulating pump, ceramic glow pin, metering pump,
switch and timer are designed for either 12 V or 24 V.
The temperature limiter, temperature sensor and flame
sensor are identical on 12V and 24V heaters.
15.2 Fuel for Thermo 90 ST (Gasoline):
The fuel specified by the vehicle manufacturer must be
used. Both leaded and unleaded fuel may be used.
Heater
EC licensing symbol
Model
Heat output
Fuel
Fuel consumption
Rated voltage
Operating voltage range
Nominal power consumption with circulation
pump (without vehicle fan)
Max. ambient temperature:
Heater:
Control module:
Metering pump:
Max. operating pressure (heat medium)
Capacity of the heat exchanger
Max. combustion air intake temperature
Minimum capacity of the system
Coolant pump delivery rate against 0.15 bar
CO
in the exhaust gases
2
(normal function range)
CO
- adjustment values at approx. + 20 °C
2
and geographic altitude above sea level
Heater dimensions (tolerance ± 3 mm)
* Control module installed on the heater
Weight
Table 1: Technical Data - Metric Measurement
www.webasto.us
±
10% at an
Operation
Max.
regulating range
Max.
regulating range
Max.
regulating range
- Operation
- Storage
- Operation
- Storage
- Operation
- Storage
Max.
Max.
Max.
15.3 Fuel for Thermo 90 ST (Diesel):
The diesel fuel specified by the vehicle manufacturer
must be used. Heating oil may also be used as long as it
complies to the normal quality available on the North
American market.
We know of no negative influences due to additives.
If fuel is extracted from the vehicle's tank, follow the
additive instructions issued by the vehicle manufacturer.
If you change to low-temperature fuel, the heater must
be operated for approximately 15 minutes so that the
fuel system is filled with the new fuel.
The Thermo 90 ST heater is also licensed for use with
PME (bio-diesel), which complies with DIN EN 14214.
Thermo 90 ST Gasoline
e1*2001/56*0019*__
Water heater with Ferro-tec technology
2.0 kW – 7.6 kW
Gasoline
0.25 l/h – 1.0 l/h
12 V
10 ... 15 V
37 W - 83 W
-40° ... +110 °C (90 °C with control module installed on the heater)
-40° ... +110 °C (90 °C with control module installed on the heater)
-40° ... +75 °C
-40° ... +20 °C
10 ... 12.0% by volume
0 m
10%
L 307 (352*) mm
31
Technical Data
Thermo 90 ST Diesel
e1*2001/56*0019*__
9.1 kW
1.8 kW – 7.6 kW
Diesel
1.1 l/h
0.19 l/h – 0.9 l/h
12 or 24 V
10 ... 15 or 20 ... 30 V
90 W
37 W - 83 W
-40° ... +85 °C
-40° ... +85 °C
-40° ... +40 °C
-40° ... +85 °C
2.0 bar
0.15 l
+40 °C
6.00 l
1650 l/h
500 m 1000 m
10.6%
11.3%
W 131 mm
H 232 mm
4,8 kg
Webasto Product N.A., Inc.