Wasserheizgeräte Einbauanweisung Water Heaters Installation Instructions Chauffages à eau Instructions de montage Thermo 90 S Thermo 90 ST Thermo 90 S (Benzin) (Petrol) (Essence) Thermo 90 S (Diesel) (Gas-oil) Thermo 90 S-ADR (Gefahrguttransport) (Transport of hazardous goods) (Transport de marchandises dangereuses)
Page 2
NEVER try to install or repair Webasto heating or cooling systems if you have not completed a Webasto training course, you do not have the necessary technical skills and you do not have the technical documentation, tools and equipment available to ensure that you can complete the installation and repair work properly.
Failure to follow the installation instructions and the notes contained therein will lead to all liability being refused by Webasto. The same use of fire resistant materials or by the use of heat shields.
Page 6
Statutory regulations governing installation Thermo 90 S / Thermo 90 ST 5.3.2.5 Every reasonable precaution should be taken in positioning the 5.3.7 Heating air outlet heater to minimize the risk of injury and damage to personal property. 5.3.7.1 Any ducting used to route the hot air through the vehicle must be so positioned or protected that no injury or damage could be caused if it 5.3.3 Fuel supply...
Page 7
Thermo 90 S / Thermo 90 ST Statutory regulations governing installation 1.3. Extract from directive ECE-R 122 Annex 9 Start of extract. 3.3.1 The combustion heaters shall be put out of operation by at least the following methods: Additional provisions applicable to certain vehicles as specified in the ADR.
The water heaters are designed for 12 V (Thermo 90 S petrol) and for The Thermo 90 S and Thermo 90 ST heaters differ from each other in 12 or 24 V (Thermo 90 S diesel).
The heater must be installed in as low a position as possible to allow the heater and circulating pump to be bled automatically. This is particularly important as the circulating pump is not self-priming. Fig. 1: Permitted installation positions for the Thermo 90 S / Thermo 90 ST...
Water circuit Without non-return valve With non-return valve and thermostat Fig. 2: Installation example for the Thermo 90 S / Thermo 90 ST heater 1 Heat exchanger, car’s heating system 7 T-piece 14 Exhaust silencer 2 Switch for car’s heating system fan...
The heater is connected to the vehicle cooling system as shown in Figure 2. The system must contain at least 6 litres of coolant. The water hoses supplied by Webasto must always be used. If you do not use these hoses, the hoses that you do use must comply with DIN 73411.
Fuel supply Thermo 90 S / Thermo 90 ST Fuel supply The fuel is taken from the vehicle fuel tank or from a separate fuel tank. The values for the maximum pressure at the fuel extraction point are shown in the table below.
Thermo 90 S / Thermo 90 ST Fuel supply 6.1. Vehicles with diesel engines The fuel must be taken from the vehicle fuel tank or from a separate tank (see Figs. 4, 5 and 6). Plastic tank Sealing ring Fuel extractor Sealing ring Fig.
Page 14
Fuel supply Thermo 90 S / Thermo 90 ST 6.2. Vehicles with petrol engines The heater must be integrated into the return line of fuel systems in carburettor and injection engines with a return line. In carburettor engines without a return line the heater must be integrated into the fuel system in the supply line between the fuel tank and the vehicle pump.
Page 15
Thermo 90 S / Thermo 90 ST Fuel supply NOTE: Correct Cut Mecanyl lines without burr and do not crush them. Do not cut them with side-cutting pliers. Clip Since the lines normally cannot be routed with a constant rising gradient, the internal diameter must not be allowed to exceed a certain size.
Page 16
Its installation position is limited as shown in Figs. 9 and 10 in order to ensure effective auto-bleeding. 6.5. Fuel filter Only a Webasto filter, order no. 487 171, is allowed to be used if the fuel is expected to be contaminated. Install vertically if possible, however at least horizontally. NOTE:...
Thermo 90 S / Thermo 90 ST Combustion air supply Combustion air supply Under no circumstances may the combustion air be taken from areas occupied by people. The combustion air intake opening must not point in the direction of travel. It must be located so that it cannot become clogged with dirt or snow and cannot suck in splashing water.
Exhaust pipe Thermo 90 S / Thermo 90 ST Exhaust pipe The exhaust pipe (internal diameter 38 mm) can be installed with a The exhaust pipe opening must be located so that it cannot become length of 0.5 m to 5 m and several bends (360° alto gether, minimum clogged with snow and mud.
If there is no earth via Y2 or H5 at control module input X12/5 (Thermo 90 S) or X8/5 (Thermo 90 ST) when it is switched on, all the ADR functions are disabled. After activating the positive potential at control module input X12/5...
Page 20
Thermo 90 S / Thermo 90 ST position shown in Figure 13. If the “Engine on”/”Engine off” signal (terminal D+) is applied to control module plug X12 contact 7 (Thermo 90 S) or plug X8 contact 7 (Thermo 90 ST), different regulating thresholds take effect Nominal...
Thermo 90 S / Thermo 90 ST Circuit diagrams Circuit diagrams 10.1. Circuit diagram legend for the Thermo 90 S and Thermo 90 ST Temperature coding (temperature at water outlet): See table on page 50 Digital timer P2: with positive at connection 10 = Continuous operation...
Page 22
Circuit diagrams Thermo 90 S / Thermo 90 ST 10.2. Thermo 90 S circuit diagram legend Item Designation Comment 1 or 2-pin disconnecting switch Emergency off switch, electric or Item Designation Comment pneumatic Heater Pumping device switch to positive Control module...
Page 23
Thermo 90 S / Thermo 90 ST Circuit diagrams ϑ ϑ Fig. 15: System circuit for Thermo 90S, 12 and 24 V, with standard timer, see pages 51 and 52 for legend...
Page 24
X13 (S T 3) X12 (S T 2) (S T 1) (S T 3) 1 12 Fig. 16: System circuit for Thermo 90 S, 12 and 24 V, with standard timer and separate circulating pump control, see pages 51 and 52 for legend...
Page 25
Thermo 90 S / Thermo 90 ST Circuit diagrams ϑ ϑ Fig. 17: System circuit for Thermo 90 S – ADR, 24 V, with switch, see pages 51 and 52 for legend...
Page 26
Circuit diagrams Thermo 90 S / Thermo 90 ST ϑ ϑ Fig. 18: System circuit for Thermo 90 S – ADR, 24 V, with switch without auxiliary drive, see pages 51 and 52 for legend...
Page 27
Thermo 90 S / Thermo 90 ST Circuit diagrams 10.3. Thermo 90 ST circuit diagram legend Item Designation Comment 1 or 2-pin disconnecting switch Emergency off switch, electric or Item Designation Comment pneumatic Heater Pumping device switch to positive Control module...
Page 28
Circuit diagrams Thermo 90 S / Thermo 90 ST Fig. 19: System circuit for Thermo 90 ST, 24 V, with standard timer, see pages 51 and 57 for legend...
Page 29
Thermo 90 S / Thermo 90 ST Circuit diagrams Fig. 20: System circuit for Thermo 90 ST, 24 V, with standard timer and separate circulating pump control, see pages 51 and 57 for legend...
Page 30
Circuit diagrams Thermo 90 S / Thermo 90 ST Fig. 21: System circuit for Thermo 90 ST – ADR, 24 V, with switch, see pages 51 and 57 for legend...
Page 31
Thermo 90 S / Thermo 90 ST Circuit diagrams Fig. 22: System circuit for Thermo 90 ST – ADR, 24 V, with switch without auxiliary drive, see pages 51 and 57 for legend...
Initial start-up Thermo 90 S / Thermo 90 ST Initial start-up NOTE: Refer to the safety instructions in the operating and maintenance instructions. The operating and maintenance instructions must be read through without fail before starting the heater. After you have installed the heater, bleed the water system and the fuel supply system carefully.
12.2. Diagnostic after a fault lock-out Fuel is supplied for max. 240 seconds if the flame does not start to burn. for the Thermo 90 S and Thermo 90 ST Check the fuses and plug connectors. Fuel is supplied for max. 240 seconds if the flame goes out during operation.
Page 34
Troubleshooting Thermo 90 S / Thermo 90 ST 12.2.2. Version with switch If the system is operated with a switch, the nature of the fault is indicated by a flashing code on an indicator light during the run-on time of the heater.
12 V or 24 V. The temperature limiter, temperature sensor and flame sensor are identical on 12 V and 24 V heaters. 13.2. Fuel for Thermo 90 S and Thermo 90 ST petrol: The fuel specified by the manufacturer must be used.
Page 36
Technical data Thermo 90 S / Thermo 90 ST Heater Operation Thermo 90 S / ST Thermo 90 S diesel Thermo 90 ST diesel Petrol Thermo 90 S-ADR Thermo 90 ST-ADR EC/ECE licensing symbol e1 00 0005 (Thermo 90 S, heater)
Page 37
Thermo 90 S / Thermo 90 ST Technical data Heater Operation Thermo 90 S / ST Thermo 90 S diesel Thermo 90 ST diesel Petrol Thermo 90 S-ADR Thermo 90 ST-ADR Heater dimensions (tolerance ± 3 mm) L 310 (355*) / 307(352*) mm...
Page 38
ø38 48,6 98,6 ø74 137,1 Thermo 90 ST ø ø ø Combustion air intake Exhaust fume outlet Fuel intake Coolant intake ø Coolant outlet ø ø ø Fig. 23: Dimensions of the Thermo 90 S / Thermo 90 ST heaters...
Page 40
Landesvertretung. In multilingual versions the German language is binding. The telephone number of each country can be found in the Webasto service center leaflet or the website of the respective Webasto representative of your country. Dans le cas d'une version rédigée en plusieurs langues, l'allemand est alors la langue qui fait foi.