Configuration (Dmx); Dmx Personalities; Dmx Control - Chauvet COLORDASH PAR-Q12 IP User Manual

Hide thumbs Also See for COLORDASH PAR-Q12 IP:
Table of Contents

Advertisement

O
PERATION
M
L
AIN
EVEL
White Balance
Manual
LED Frequency
Backlight
Key Lock
Information
Reset Factory

Configuration (DMX)

Use DMX configurations to operate the product with a DMX controller.

DMX Personalities

This setting allows you to choose a particular DMX personality.
1.
Go to the DMX Channel main level.
2.
Select the desired personality (4 Ch, 6Ch, or 11 Ch).
See the
each personality.
Make sure that the starting addresses on the various products do not overlap due
to the new personality setting.

DMX Control

In this mode, each product will respond to a unique starting address from the DMX controller. All products
with the same starting address will respond in unison.
1.
Select a DMX personality as shown in
2.
Set the starting address:
a.
Go to DMX Address main level.
b.
Select the starting address (001–512).
The highest recommended starting address for each DMX mode is as follows:
COLORdash Par-Q12 IP User Manual Rev. 1
P
L
ROGRAMMING
EVELS
Off
R
G
125-255
B
A
600Hz
1200Hz
2000Hz
4000Hz
25kHz
On
10S
20S
30S
On
Off
Fixture Hours
Version
No
Yes
DMX Values
section for the highest starting address you can select for
DMX
DMX PERSONALITY
11
6
4
D
ESCRIPTION
Uses factory default white setting
Sets red LED maximum value
Sets green LED maximum value
Sets blue LED maximum value
Sets amber LED maximum value
Selects the PWM output frequency
Display backlight always on
Turns off display backlight after 10 sec of
inactivity
Turns off display backlight after 20 sec of
inactivity
Turns off display backlight after 30 sec of
inactivity
Turns the passcode on or off
Shows total product hours
Shows installed software version
Reset all settings to factory defaults
Personalities.
DMX ADDRESS
502
507
509
Page 11 of 19