Test And Inspection Plan; User Interface Test; Rf Test; Philips Electronics N.v - Philips 655 CT6558 Service Manual

Table of Contents

Advertisement

Depart. Technical support- CM640
PHILIPS Consumer
Communications
Centre du Mans
6.0

TEST AND INSPECTION PLAN

The test plan is derived from the Product Test Reference of PHILIPS 655.
6.1

User Interface Test

Use the Test SIM Card to test the transceivers as follows :
With a fast Charger connected with the PRODUCT's bottom connector, check the full scrolling from one mode to
the next when charging IGN (Ignition) – Battery.
6.2

RF Test

The purpose of the radio test is to prove that the tested phone is compliant to the Standard.
The radio test must be performed with a
Digital Radio Test Set. The mobile has to
be set on the antenna coupler inside the
shielded chamber.
Due to a not accessible RF connector when the Product is closed, it will be necessary to make radio test inside
Shielded chamber only.
See Help Radio Files Over the antenna - RF Calibration.pdf & Over the antenna - The equipments.pdf under the
Internet Web Site :
http://philipscscc.soft2you.net/
Use the Test SIM Card « SP »to test the GSM 900 / DCS 1800 band
 PHILIPS ELECTRONICS N.V. 1999
All rights reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.
PROCEDURE
Service Repair Support
On/Off button
LCD Backlight
Keyboard Test
Side Keys
Buzzer Test
Vibrator Test
Audio Test
Antenna Test ( to measure the radiated power level. Not necessary when using an
antenna coupler)
LCD
IMEI
Tester Status/Eeprom Status
in " Technical Support \ Component List \ Wireless \ PHILIPS 639 " section
COMPANY RESTRICTED
VY-V-640-P655
Page : 5 of 74
Langue : EN
Date : 03/01/05
VY-V-640-P655

Advertisement

Table of Contents
loading

Table of Contents