8.3.2
Current consumption
a) Check current_OFF :
When the mobile is OFF the current measured must be : 0.00 < I (mA) < 1
b) Check Current_ON
- Turn the mobile on.
Measurement during first seconds after switch on :
190 < I (mA) < 220
During Welcome message animation, the current measured must be:
240 < I (mA) < 330
When the mobile is ON (backlight activated) after 15-30 seconds the current
measured must be: