Using Leds To Diagnose Problems - Hitachi CBXSS Hardware Service Manual

Unified storage
Table of Contents

Advertisement

Using LEDs to diagnose problems

Table 17-2
Hitachi Unified Storage systems.
If the storage system used in a remote TrueCopy Remote Replication/
TrueCopy Extended Distance configuration restarts with the TrueCopy
Remote Replication/TrueCopy Extended Distance status of enabled, the
following occur.
The path used by TrueCopy Remote Replication/TrueCopy Extended
Distance becomes blocked. Notifications from the Storage Navigator
Modular 2 e-mail alert function, SNMP Agent Support function, and
TRAP occur when the path is blocked. Follow the instructions in the
notification. The blocked path recovers automatically after restarting
the storage system.
If the TrueCopy Remote Replication/TrueCopy Extended Distance pair
status is PAIR or COPY, the pair changes to PSUE. In this case, suspend
the pairs before restarting the storage system.
If using Power Saving/Power Saving Plus and the power saving setting
I/O interlock disabled is executed, starting the storage system with
the power saving status set to Normal (Command Monitoring)
changes the status to Normal (Spindown Failed: PS OFF/ON). After
performing the I/O interlock disabled operation, check that there is
no RAID group whose power saving status is Normal (Command
Monitoring) and then restart the storage system.
POWER LED does not go ON
17–10
describes how to troubleshoot problems using the LEDs on
Table 17-2: Using LEDs to diagnose problems
Problem
2. Is the POWER LED on the Controller Box ON?
3. Is the POWER LED on the Controller Box ON?
4. Check that the storage system is receiving
5. Verify that the AC cable is correctly connected
6. Set the main switch to on.
7. Is the POWER LED on the Controller Box ON?
8. Contact your administrator. Go to step 10.
9. Is the READY LED ON?
10. End of procedure.
Troubleshooting
Hitachi Unified Storage Hardware Service Guide
Corrective action
1. Set the main switch to on.
Yes: Go to step 10.
No: Power on the host computer.
Yes: Go to step 10.
No: Set the main switch to off.
power.
to the plug socket and the equipment.
Yes: Go to step 10.
No: Set the main switch to off.
Yes: Continue to use the equipment, even if
the green READY LED blinks fast.
No: See
READY LED does not go ON or READY
LED went ON and then OFF on page
17-12.

Advertisement