Copying and installing firmware

The firmware is located in a compressed (zip) file under
Firmware\program\microprogram on the supplied DVD. Copy it to the
following location on the maintenance PC:
C:\diskarray-microprogram\microprogram
manual
program
After copying the firmware file, use the following procedure to install the
firmware on the CBSL/CBSS. You perform this configuration two times.
1. At the Hitachi Storage Navigator Modular 2 Arrays page, check the
storage system on which you will install the firmware.
2. Press the Ctrl, Shift, and E keys at the same time to switch to
Maintenance Mode. Confirm that Maintenance Mode appears next to
Operation Mode on the Arrays page (see
3. Under the Array Name column, confirm that the name of the Hitachi
Unified Storage system is checked in the Arrays page.
4. In the middle pane, click Settings > Firmware.
5. On the right side of the Firmware page, find the firmware revision shown
next to Revision and record it below
Record the local file revision here: ......................
6. Click the Update Firmware button. The Update Firmware page
appears, with the Basic tab displayed.
Table 15-2: DVD File Structure
Root level
hostInst
UG
microprogram
DFJavaSetup.exe
(Java setup file)
Upgrading a Hitachi Unified Storage 130 system
Hitachi Unified Storage Hardware Service Guide
First subfolder
manual file
Firmware zip file
Figure 15-1 on page
Second subfolder
15-10).
15–13