Ignition Lockout; Operation - IDEAL VOGUE SYSTEM S15 User Manual

Gen2
Hide thumbs Also See for VOGUE SYSTEM S15:
Table of Contents

Advertisement

TO LIGHT THE BOILER. (REFER TO BOILER
CONTROLS)
1.
Switch ON electricity to the boiler and check that all
external controls, e.g. programmer and room thermostat,
are ON.
2.
Set the Central Heating temperature control (D) to 'max'.
3.
Set "off/on" control (E) to "on".
The boiler will commence the ignition sequence supplying
heat, if required.
Note. In normal operation the boiler colour screen will display
the boiler operation mode.
Boiler frost protection - boiler will fire if temperature is less
than 5 degrees C.
During normal operation the burner on indicator (B) will remain
illuminated when the burner is lit.
If the boiler has not lit, after 5 ignition attempts, the following
screen will be displayed.

IGNITION LOCKOUT

Check other gas appliances work
If pre-payment meter check credit
If not, contact gas supplier
Restart boiler.
If fault persists contact installer
01482 498663
RESTART
Reset the boiler and the ignition sequence will be repeated.
EXIT

OPERATION

Central Heating
With the external heating controls calling for heat, the "off/on"
control (E) set to 'on' and the Central Heating Temperature
Control (D) turned fully clockwise, the boiler will operate to
provide heat to the system. Note this will also provide heat to
the hot water system whose temperature will be controlled by
the independent cylinder thermostat.
When the cylinder thermostat is satisfied the system valves
will operate to direct all flow to the Central Heating circuit. If
the cylinder thermostat calls for heat the system valves will
operate to circulate hot water around the cylinder to heat the
stored water.
Note. If the pump has not operated in the last 24 hours it will
run briefly to ensure it does not become seized.
The boiler controls the central heating radiator temperature
to a maximum of 80
o
temperature control (D).
Central Heating Knob Setting
Minimum
Maximum
7
C, adjustable via the Central Heating
Flow Temp
30ºC
80ºC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vogue system s18Vogue system s26Vogue system s32

Table of Contents