WEATHER COMPENSATION

When the Weather Compensation option is fitted to the system
then the Central Heating Temperature Control (D) becomes
a method of controlling room temperature. Turn the Central
Heating Temperature Control knob (D) clockwise to increase
room temperature and anti-clockwise to decrease room
temperature. Once the desired setting has been achieved,
leave the knob in this position and the system will automatically
achieve the desired room temperature for all outside weather
conditions.
TO SHUT DOWN THE BOILER
Set the off/on switch (E) to "off".
TO RESTART THE BOILER
Repeat the procedure detailed in 'To light the boiler' (page 7).
Set the off/on control to 'on' and set the temperature control to
between 30ºC & 80ºC, referring to colour screen whilst adjusting.

FROST PROTECTION

If no frost protection is provided and frost is likely during a short
absence from home, leave the heating controls (if fitted) at a
reduced temperature setting. For longer periods, the entire
system should be drained.
If the system includes a frost thermostat then the timer can be
left off (if fitted). The mains supply should be left switched ON,
with the boiler thermostat left in the normal running position.
BOILER OVERHEAT PROTECTION
The boiler controls will shut down the boiler in the event of
overheating. Should this occur, the following screen will display:

OVERHEAT LOCKOUT

With boiler o & system cold fill System to 1.0 Bar
Bleed radiators and refill system to 1.0 Bar
Check radiator valves are open.
Restart boiler.
If fault persists contact Installer
01482498660
RESTART