Priming The Chemical Pump; Waste Pumpout (Optional); Cleaning - Prochem EVEREST 650 Operating Instructions Manual

Everest 650 high pressure 1.001-145.0 everest 650 low pressure 1.001-146.0 everest 408 high pressure 1.001-151.0 everest 408 low pressure 1.001-152.0
Hide thumbs Also See for EVEREST 650:
Table of Contents

Advertisement

Priming The Chemical Pump

1. Fill chemical container and inspect chemical
strainer.
2. Insert chemical inlet tube into chemical container.
3. Turn ignition key to start.
4. Set throttle to low speed.
5. Turn solution pump on.
6. Turn Chemical valve to prime and allow chemical
to circulate. After all air bubbles have been
removed from chemical tube, turn the valve to the
Chem position.
7. Turn chemical flow setup valve to setup position.
Use the chemical metering valve to set the
chemical flow to the desired flow rate while
observing the flow meter indicator. Turn the
chemical flow setup valve to Chem position.
8. Set throttle to maximum position for quick unit heat
up.
Once you have completed priming the chemical pump,
proceed with the cleaning operation. Your unit should
be in the correct throttle position for your cleaning
operation or extracting.
NEVER dispose of waste in storm drains, waterways,
or on ground areas. Always dispose of waste in accor-
dance with Local, State, and Federal laws.

Waste Pumpout (Optional)

1. If your unit is equipped with an automatic waste
pump, connect one end of a garden hose to the
pump-out connection and the other end to an
appropriate waste disposal.
2. Turn the pump-out switch on the control panel to
the ON position. The waste pump will operate auto-
matically throughout the cleaning operation.
We recommend that you use a 3/4" I.D. water hose
as a waste pump outlet hose. DO NOT use a hose
smaller than 5/8" I.D.
NEVER use your automatic waste pump outlet
hose as a water inlet hose.

Cleaning

Observe the following guidelines, while cleaning:
1. Before proceeding make sure the spray tips are
functioning properly.
a. To check, hold the wand about one foot above
the surface to be cleaned and open the wand
valve. A full spray should be observed from all of
the cleaning spray tips.
b. If the spray tips are not showing a full spray
pattern, adjust for proper pattern, clean, or
replace spray tips, if required.
2. Normally chemical is applied on the push stoke of
the wand, and cleaning and vacuuming is done on
the pull stroke. For heavily soiled carpets the wand
may be used in a scrubbing manner, applying
chemical in both push and pull strokes. Always
finish up an area with a vacuum stroke.
3. When cleaning, keep the working opening (mouth)
flat on the surface being cleaned. Keep the wand
moving when the valve is open.
The unit will automatically shut-down when the waste
tank is full. This will prevent water being drawn into the
vacuum pump. If shut-down occurs, empty the waste
tank before proceeding. If shutdown occurs due to foam
created by chemicals used, add Prochem defoamer.