MTU 12 V 4000 L62FB Operating Instructions Manual page 85

Table of Contents

Advertisement

1.4510.207 – Knock Sensor Error B6
Red alarm. Initiated by anti-knock control.
Cause
No signal from this knock sensor.
1.4510.208 – Knock Sensor Error B7
Red alarm. Initiated by anti-knock control.
Cause
No signal from this knock sensor.
1.4510.209 – Knock Sensor Error B8
Red alarm. Initiated by anti-knock control.
Cause
No signal from this knock sensor.
1.4510.210 – Knock Sensor Error B9
Red alarm. Initiated by anti-knock control.
Cause
No signal from this knock sensor.
1.4510.211 – Knock Sensor Error B10
Red alarm. Initiated by anti-knock control.
Cause
No signal from this knock sensor.
1.4530.007 – Shutdown
Red alarm. Initiated by F-series.
Cause
Hardware not ready for operation.
1.4530.008 – Alarm
Yellow alarm. Initiated by F-series.
Cause
Combined alarm (for details, refer
to the source alarm).
Corrective action
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as necessary.
Corrective action
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as necessary.
Corrective action
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as necessary.
Corrective action
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as necessary.
Corrective action
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as necessary.
Corrective action
u Restart F-series.
Corrective action
u Combined alarm (for details, refer to the source alarm).
MS150098/02E 2016-11 | Troubleshooting | 85

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8v 4000 l62 fb

Table of Contents