MTU 12 V 4000 L62FB Operating Instructions Manual page 60

Table of Contents

Advertisement

112419 – LO T-Exhaust B9
Yellow alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
high in comparison with weighted
average.
112420 – LO T-Exhaust B10
Yellow alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
high in comparison with weighted
average.
112501 – HIHI T-Exhaust A1
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
high in comparison with weighted
average.
112502 – HIHI T-Exhaust A2
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
high in comparison with weighted
average.
112503 – HIHI T-Exhaust A3
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
high in comparison with weighted
average.
60 | Troubleshooting | MS150098/02E 2016-11
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 140).
4. Check valve drive.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 140).
4. Check valve drive.
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 140)
3. Check valve drive (exhaust valves do not close).
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 140).
3. Check valve drive (exhaust valves do not close).
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 140).
3. Check valve drive (exhaust valves do not close).

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8v 4000 l62 fb