MTU 12 V 4000 L62FB Operating Instructions Manual page 64

Table of Contents

Advertisement

112519 – HIHI T-Exhaust B9
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
high in comparison with weighted
average.
112520 – HIHI T-Exhaust B10
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
high in comparison with weighted
average.
112601 – LOLO T-Exhaust A1
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
high in comparison with weighted
average.
112602 – LOLO T-Exhaust A2
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
high in comparison with weighted
average.
112603 – LOLO T-Exhaust A3
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
high in comparison with weighted
average.
64 | Troubleshooting | MS150098/02E 2016-11
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 140).
3. Check valve drive (exhaust valves do not close).
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 140).
3. Check valve drive (exhaust valves do not close).
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 140).
4. Check valve drive.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 140).
4. Check valve drive.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 140).
4. Check valve drive.