(2) Detaching and refitting the fuser thermistor 1, fuser thermostat 1, fuser heater lamp, heat roller, and press belt
Procedure
1. Remove the fuser unit (See previous page).
2. Remove the one screw and then the termi-
nal and nut.
3. Remove the two connectors.
4. Remove the wire from wire clamp.
5. While unlatching the latch and then remove
the fuser L cover.
Downloaded from
www.Manualslib.com
manuals search engine
Terminal
Nut
Figure 1-5-50
Connector
Fuser L cover
Screw
Latch
Figure 1-5-51
2HJ/2HK
Screw
Connector
Wire
Wire clamp