6 Installation Details
MAIN
PCB
BLUE
Ctl
CAPACITOR
6.1 Wrench torque sheet for Installation
Outside
diameter
Torque
mm
inch
N.cm
4>6.35
1/4
1500(153kgf.cm)
4>9.52
3/8
2500(255kgf.cm)
4>12.7
1/2
3500(357kgf.cm)
4>15.9
5/8
4500(459kgf.cm)
4>19
3/4
6500(663kgf.cm)
6.2 Connecting the cables
Additional
tightening torque
N.cm
1600(163kgf.cm)
2600(265kgf.cm)
3600(367kgf.cm)
4700(479kgf.cm)
6
700(683kgf
.cm)
The
power
cord
of
connect should be
selected according
to the following
specifications sheet.
Rated current of appliance
Nominal
cross-sectional area (mm
2
)
>3
and
s6
0.75
>6
and
s10
1
>10 and
S16
1.5
>16
and
S25
2.5
The cable size and
the
current of
the fuse
or
switch
are
determined by the maximum
current Indicated
on
the nameplate which located
on the side
panel
of the
unit. Please refer to the nameplate before
selecting
the
cable, fuse
and
switch.