1.
Restore electrical power to the outlet box by turning
the electricity on at the main fuse box (Figure 1).
Check to see that all connections are tight, including
earth, and that no bare wire is visible at the wire
connectors, except for the earth wire. Do not operate
fan until the blades are in place. Noise and fan
damage could result.
NOTE: Receiver in controllers system features an
automatic learning function. There are no frequency
switches on the receiver unit. The receiver will
automatically scan the frequency from the hand held
control if an changes are made. the frequency settings
should be changed only in the case of interference or
if multiple ceiling fans with the same type of control
system are installed in the same structure.
2. To make the fan operational, install 23A/12V battery
(included) into the hand-held remote transmitter (If not
used for long periods of time, remove the battery to
prevent damage to the transmitter). With fan power off.
Then follow the remote code setting process. Store the
remote away from excessive heat or humidity. (Figure 2)
3. Remote Control Setting and Speed (RPM)
Setting Process : (Figure 3)
1. When powering on your fan, do not press any
button(s) before pressing the "SET" button,
otherwise it will fail the learn procedure. If you press
a button before the "Set" button, please turn the
power off then on again, and start the process again.
2. After installing the unit and restoring power to
your fan, press and hold the "SET" button 1~5
seconds. You must press the "SET" button within 60
seconds of restoring power to the fan.
3. The fan will start to run and begin the control
setting process.
4. DO NOT press any button(s) after pressing the SET
button and while the fan is programming or it will fail
to program. The fan will run in both directions for a
total of approximately 5 minutes.
5. When the fan stops after approximately 5 minutes
the control and speed setting process is complete.
The fan is now ready for normal use.
NOTE: If you need to change the blades: turn
the power off→ change the blades →turn the
power on →perform the control setting process
again.

How to Operate Your Ceiling Fan

WARNING
11
MAIN FUSE BOX
Figure 1
Figure 2
Figure 3

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the The Odyn and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Fpd8148au series

Table of Contents