Rtc Backup Battery; Buzzer - Nokia NSE–3 SERIES Service Manual

Table of Contents

Advertisement

NSE–3
System Module

RTC Backup Battery

The RTC block in CCONT needs a power backup to keep the clock run-
ning when the phone battery is disconnected. The backup power is sup-
plied from a rechargable polyacene battery that can keep the clock run-
ning minimum of 10 minutes. The backup battery is charged from the
main battery through CHAPS.
Signal
Parameter
VBACK
Backup battery charg-
ing from CHAPS
Backup battery charg-
ing from CHAPS
VBACK
Backup battery supply
to CCONT
Backup battery supply
to CCONT

Buzzer

Signal
Maximum
output cur-
rent
BuzzPWM /
2mA
BUZZER
Page 3 – 16
Min
Typ
Max
3.02
3.15
3.28
100
200
500
2
3.28
80
Input
Input
high level
low level
2.5V
0.2V
PAMS
Technical Documentation
Unit
Notes
V
uA
Vout@VBAT–0.2V
V
Battery capacity
65uAh
uA
Level (PWM)
Frequency
range, %
range, Hz
0...50 (128 lin-
440...4700
ear steps)