SAFETY INFORMATION
Use this appliance only as described in the manual. Any other use is NOT recommended by the manufacturer and
may cause fire, electric shock or injury to persons.
CAUTION
• If possible, ALWAYS unplug this appliance when not in use.
• DO NOT operate any heater with a damaged cord or plug or after the heater malfunctions.
• DO NOT operate any heater if it has been dropped or damaged in any manner. Disconnect power at service
panel and have heater inspected by a reputable electrician before reusing.
• Any repairs to this fireplace should be carried out by a qualified service person.
• Under no circumstances should this fireplace be modified. Parts having to be removed for servicing must be
replaced prior to operating this fireplace again.
• DO NOT use outdoors.
• This heater is not intended for use in bathrooms, laundry areas and similar indoor locations. NEVER place heater
where it may fall into a bathtub or other water container.
• To disconnect this appliance, turn controls to the off position, then remove plug from outlet.
• ONLY connect to properly grounded outlets.
• This appliance, when installed, must be electrically grounded in accordance with local codes, with the current
CSA C22.1 Canadian Electrical Code or follow the National Electrical Code, ANSI/NFPA N0.70.
• To prevent a possible fire, DO NOT block air intakes or exhaust in any manner. DO NOT use on soft surfaces, like
a bed, where opening may become blocked.
• The heaters MUST NOT be located immediately below a socket-outlet.
• ALWAYS plug heaters directly into a wall outlet/receptacle. NEVER use with an extension cord or relocatable
power tap (outlet/power strip).
• There is a thermostat protective device provide inside of unit. If the inner temperature overheats or abnormal
heating occurs, the thermostat protective device will cut off power supply to prevent damage or risk of fire.
• DO NOT place any objects on top of insert and top air intake vents as this will cause unit to overheat and can
cause a fire.

Electrical Connection

A 15-amp, 120-volt, 60 Hz circuit with a properly grounded outlet is
required. Preferably, the fireplace will be on a dedicated circuit as other
appliances on the same circuit may cause the circuit breaker to trip or
the fuse to blow when the heater is in operation. The unit comes
standard with 6-ft. three-wire cord, exiting from the rear of the
fireplace. DO NOT exceed the current rating of the current tap. ALWAYS
plug heaters directly into a wall outlet/receptacle. NEVER use with an
extension cord or relocatable power tap (outlet/power strip).
This heater is for use on 120 volts. The cord has a plug as shown
below. See illustration for grounding instruction. An adapter as shown
at C is available for connecting three-blade grounding type plugs to
two-slot receptacles. The green grounding lug extending from the
adapter must be connected to a permanent ground such as a properly
grounded outlet box. The adapter should not be used if a three-slot
grounded receptacle is available.
SAVE THESE INSTRUCTIONS
ELECTRICAL SPECIFICATIONS
Voltage: 120 VAC, 60 Hz
Amps:
11.7 Amps
Watts: 1400 Watts
Metal
Screw
Cover of
Grounding
Grounding Pin
Box
A
B
C
D
Grounding Means
Adapter
Grounding Pin
3