40 Technical data
Rectifier power capacity (P
Frame
P
rec,ave
R1
5.5
R2
11
R3
18.5
R4
30
R5a
15
R5b
45
R6
75
R7
110
R8
160
R9
250
R10a
250
R10b
355
R11
1)
500/630
U
: AC input voltage.
ac
P
is the average rectifier power capacity of the drive over a 3-minutes time window. The average power
rec,ave
taken from AC power line must be lower than this value during any 3-minutes time window.
1)
Value 630 applies to 600...690 V AC.
P
is the maximum rectifier power capacity of the drive allowed for max. 10 s. The instantaneous power
rec,max
taken from AC power line must never exceed this limit.
R5a: ACS880-01 types -07A3-7, -09A8-7, -14A2-7 and -018A-7.
R5b: ACS880-01 types -022A-7, -026A-7, -035A-7, -042A-7 and -049A-7.
R10a: ACS880-04 types -505A-3 and -460A-5.
R10b: ACS880-04 types -585A-3, -650A-3, -583A-5, -635A-5, -330A-7 and -370A-7.
rec,ave
208...240 V AC
380...415 V AC
(ACS880-01
(ACS880-01/-04
-xxxx-2)
7
13
26
37
-
63
92
153
228
-
-
-
-
and P
rec,max
P
depending on U
rec,max
380...500 V AC
(ACS880-01/-04
-xxxx-3)
-xxxx-5)
7
13
26
37
-
63
92
153
144
228
212
317
262
340
420
420
500
620
700
)
ac
600...690 V AC
(ACS880-01/-04
-xxxx-7)
6
-
10
-
24
-
32
-
-
24
59
54
79
81
150
208
304
-
510
850