PSC Mini PowerWedge User Manual page 25

Fixed-station decoder
Table of Contents

Advertisement

3.
Remove the bar code reader from the master, and connect the
cloning cable (part number 00-874-25) to the input connector
on the master.
NOTE
4.
The Mini PowerWedge that you want to program is called
the "slave." Set the On/Off/Program switch on the slave to
the
OFF
5.
Connect the free end of the cloning cable to the input connec-
tor on the slave.
6.
Set the On/Off/Program switch on the slave to the
position.
The parameter settings from the master Mini PowerWedge
will immediately be copied into the slave. The slave will indi-
cate successful programming by beeping three times and
repeatedly flashing its green LED twice.
7.
Turn the slave off and disconnect the cable from it.
8.
Repeat steps 4 through 7 to make additional clones. Then
turn the master off and remove the cable from it.
NOTE
User's Guide
To make your own cloning cable, see the pinout dia-
gram in the Mini PowerWedge Programming Refer-
ence.
position.
Leaving the master unit in cloning mode for longer
than necessary may cause it to overheat.
PRGM
21