115V Auxiliary Output Issues; Water Cooler Issues - Lincoln Electric ASPECT 375 Operator's Manual

Ac/dc tig welder
Hide thumbs Also See for ASPECT 375:
Table of Contents

Advertisement

ASPECT™ 375

115V AUXILIARY OUTPUT ISSUES

SYMPTOMS
No output

WATER COOLER ISSUES

NOTE: If cooler control cable is connected to or disconnected from machine when machine is already turned on,
machine must be recycled by turning off and then on so that cooler is recognized by machine; failure to do this
may damage Tig torch when welding
SYMPTOMS
Indicator light on cooler
does not turn on
Tig torch runs hot
Machine displays
ERR 11 when welding
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
Observe all Safety Guidelines detailed throughout this manual
POSSIBLE CAUSE
Overload trips 115V circuit breaker
Overload trips internal thermostat
Faulty receptacle or connection
Faulty PC Boards or connections
POSSIBLE CAUSE
Cooler is not plugged in
No 115V output
Cooler control cable is not plugged in
Insufficient water in cooler
Air in water line
Cooler is not plugged in to 115V
receptacle, insufficient coolant in cooler,
TIG Torch is undersized (amperage
capacity) for application, blown fuse, or
faulty flow sensor inside cooler.
RECOMMENDED COURSE OF ACTION
Remove load & reset breaker
Remove load & wait for thermostat
to reset
Check receptacle and
connection
Contact your local Lincoln
Authorized Field Service Facility
RECOMMENDED COURSE OF ACTION
Plug cooler to 115V receptacle
Refer to 115V auxiliary outputsection
Turn machine off, plug control
cable, then turn machine on
Check and refill water
Activate trigger and depress
Flow Sensor Bypass switch to
prime cooler
Initial Correction Measures: Check
Cooler Connections, Fill Cooler with
additional Low Conductivity Coolant
(KP4159-1), Replace with higher
amperage capacity TIG Torch. Replace
3A fuse. Depress Flow Sensor Off
button to remove error code.
Secondary Corrective Measures:
Service cooler
CAUTION
E-10
TROUBLE SHOOTING

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents