Error Code List - Lincoln Electric ASPECT 375 Operator's Manual

Ac/dc tig welder
Hide thumbs Also See for ASPECT 375:
Table of Contents

Advertisement

ASPECT™ 375

ERROR CODE LIST

CODE
DESCRIPTION
01
Low input
02
High input
AC switch
05
overload
Inverter Under
06
Voltage Lock Out
Water Cooler
11
Fault
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
Observe all Safety Guidelines detailed throughout this manual
POSSIBLE CAUSE
Input voltage is lower than 200V or
drops below 200V under load
Input voltage is higher than 600V or
spikes above 600V under load
Output overload
Internal +15V supply is too low
Cooler is not plugged in to 115V receptacle,
insufficient coolant in cooler, TIG Torch is
undersized (amperage capacity) for application,
blown fuse, or faulty flow sensor inside cooler.
CAUTION
E-2
TROUBLE SHOOTING
CORRECTIVE
ACTION
Check input voltage,
cable size, and fuse
size.
Check input voltage.
Cycle power to clear the
fault. If problem persists,
contact Lincoln Authorized
Service Facility.
Cycle power to clear the
fault. If problem persists,
contact Lincoln Authorized
Service Facility.
Initial Corrective Mea-
sures:
Check Cooler Connections,
Fill Cooler with additional
Low Conductivity Coolant
(KP4159-1), Replace with
higher amperage capacity
TIG Torch. Replace 3A
fuse. Depress Flow Sensor
Off button to remove error
code.
Secondary Corrective
Measures:
Service cooler