TECHNICAL SPECIFICATIONS ASPECT
(K3945-1, K3945-2)
POWER SOURCE
INPUT VOLTAGE AND CURRENT
Duty Cycle
(1 Phase in Parentheses)
30%
60%
100%
Input Voltage ± 10%
208/230**/400*/460/575
50/60 Hz
(*includes 380 to 413 V)
(*includes 220 V)
RATED OUTPUT
Input Power
PHASE
THREE
PHASE
SINGLE
PHASE
OUTPUT RANGE
Phase
Type of Output
THREE
GTAW AC/DC
PHASE
SMAW AC/DC
SINGLE
GTAW AC/DC
PHASE
SMAW AC/DC
Thermal tests have been performed at ambient tem-
perature. The duty cycle (duty factor) at 40°C has
been determined by simulation.
375
Input Amperes
25/23/13/11/9
(30/27/NA/NA/NA)
29/26/15/12/10
(34/31/NA/NA/NA)
29/27/16/13/10
(34/31/NA/NA/NA)
Idle Power
Power Factor
@ Rated Output
100 Watts
.95
Max.
Duty
Rated Output
Cycle
Current and Voltage
100%
GTAW 250 A / 20 V
SMAW 250 A / 30 V
60%
GTAW 300 A / 22 V
SMAW 300 A / 32 V
30%
GTAW 350 A / 24 V
SMAW 350 A / 34 V
100%
GTAW 180 A / 17.2 V
SMAW 180 A / 27.2 V
60%
GTAW 225 A / 19 V
SMAW 225 A / 29 V
30%
GTAW 250 A / 20 V
SMAW 250 A / 30 V
Output Current
Maximum Open
Range
Circuit Voltage
2-375 Amps
108 Volts Max.
20-350 Amps
90 Volts Max.
2-250
108 Volts Max.
20-250
90 Volts Max.

RECOMMENDED INPUT WIRE AND FUSE SIZES

INPUT
MAXIMUM
VOLTAGE /
INPUT AMPERE
PHASE /
RATING
FREQUENCY
200-208/1/50/60
230/1/50/60
200-208/3/50/60
230/3/50/60
380-415/3/50/60
460/3/50/60
575/3/50/60

PHYSICAL DIMENSIONS

HEIGHT
WIDTH
21.00 in.
11.8 in.
533 mm
300 mm
OPERATING TEMPERATURE RANGE
-20°C to +40°C (-4°F to +104°F)
STORAGE TEMPERATURE RANGE
-40°C to +85°C (-40°F to +185°F)
IP23
1. Based on U.S. National electrical Code
2. Also called " inverse time" or "thermal / magnetic" circuit break-
ers; circuit breakers that have a delay in tripping action that
decreases as the magnitude of the current increases
3. Type SO cord or similar in 30° C ambient
A-1
INSTALLATION
CORD SIZE
3
TIME DELAY
AWG SIZES
FUSE OR
2
(mm
)
BREAKER
AMPERAGE
50 A
8 (8.3)
47 A
8 (8.3)
46 A
10 (5.3)
42 A
10 (5.3)
24 A
14 (2.1)
20 A
14 (2.1)
16 A
14 (2.1)
DEPTH
WEIGHT
25.00 in.
105 lbs. (48kg.)
635 mm
1
2
60
60
60
50
35
30
20

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents