Initial Input Cord Setup; Power Cord Replacement - Lincoln Electric ASPECT 375 Operator's Manual

Ac/dc tig welder
Hide thumbs Also See for ASPECT 375:
Table of Contents

Advertisement

ASPECT™ 375
WARNING
The ASPECT™ 375 ON/OFF switch is not intended as a
service disconnect for this equipment. Only a qualified
electrician should connect the input leads to the ASPECT™
375. Connections should be made in accordance with all
local and national electrical codes and the connection
diagram located on the inside of the right case side. Failure
to do so may result in bodily injury or death.

INITIAL INPUT CORD SETUP

(FOR K3945-2 ONLY)
For the initial setup of the input cord on the K3945-2 Aspect™
375, it will be necessary to assemble the provided toroid onto the
input ground lead. The toroid will be clamped to the earth ground
connection as shown in Figure A.1. Remove and discard the
clamp, loop the input ground lead 2 times through the toroid, and
then connect it with the grounding lug as shown in Figure A.2.
FIGURE A.1
FIGURE A.2

POWER CORD REPLACEMENT

Only a qualified electrician should connect the input leads to
the ASPECT™ 375. Connections should be made in
accordance with all local and national electrical codes and
the connection diagrams. Failure to do so may result in
bodily injury or death.
If the input power cord is damaged or needs to be replaced an
input power terminal block is located in the back of the machine
with the right case side removed as shown in Figure A.3.
ALWAYS CONNECT THE GROUNDING LUG (LOCATED AS SHOWN
IN FIGURE A.3) TO A PROPER SAFETY (EARTH) GROUND.
Toroid
Input
Ground
Lead
A-4
INSTALLATION
WARNING
FIGURE A.3
TOROIDAL CORE
TERMINAL BLOCK
INPUT
POWER CORD
GROUND LUG