EN 8
4.
LC4.1E AB

4. Mechanical Instructions

Index of this chapter:
4.1 Service Position
4.2 Rear Cover Removal
4.3 Power Supply Unit Removal
4.4 Small Signal Board Removal
4.5 Side I/O Panel Removal
4.7 LED/IR Panel Removal
4.8 Audio Amplifier Panel Removal
4.9 Exchanging the LCD Panel
4.10 Re-Assembly
Note: Figures below can deviate from the actual situation, due
to different set executions.
Note: To diagnose the set with ComPair it is not needed to
open the set entirely.
To access the ComPair connector, proceed with the following:
1. Manually unlock and remove the cover cap.
2. Remove the tape shielding that covers the ComPair
connector (1).
Note: Make sure that both the ComPair connector and the
UART connector are shielded off with a piece of insulating tape
after repair for ESD reasons. Place this tape over the holes in
the rear cover of the set.
Figure 4-1 ComPair connector
4.1
Service Position
4.1.1
Foam Bars
Figure 4-2 Foam bars
The foam bars (order code 3122 785 90580) can be used for
all types and sizes of Flat TVs. By laying the plasma or LCD TV
flat on the (ESD protective) foam bars, a stable situation is
created to perform measurements and alignments. By placing
a mirror under the TV, you can easily monitor the screen.
Mechanical Instructions
1
E_14520_034.eps
160904
E_06532_018.eps
170504
4.2
Rear Cover Removal
Figure 4-3 Rear cover removal
1. Make sure all power-, audio-, video- and coax- cables are
unplugged.
2. Remove all Torx screws (1) around the edges of the rear
cover.
3. Remove the rear cover and store it in a safe place.
4.3
Power Supply Unit Removal
Figure 4-4 Power supply unit (depending on model)
1. Disconnect all cables from the Power supply unit.
2. Remove all mounting screws (1) from the Power supply
unit.
3. Take out the Power supply unit.
1
E_14520_035.eps
1
E_14520_036.eps
160904
160904