ELECTRICAL SYSTEM
MAIN CONTROL BOARD FAULT CODES
Faults Non-Board
Code#
Fault Description by System Family
03 NC
Wash hose pump over current
19 NC
Horn over current
17 NC
Back Up Alarm over current
02 C
Main power relay K1 coil over current
25 C
20A Circuit breaker CB1 over current
26 C
20A Circuit breaker CB2 over current
27 C
15A Circuit breaker CB3 over current
28 C
20A Circuit breaker CB4 over current
29 C
10A Circuit breaker CB5 over current
20 NC
Left turn signal lamp over current
21 NC
Right turn signal lamp over current
22 NC
Head and tail lamp over current
23 NC
Left stop lamp over current
24 NC
Right stop lamp over current
14 NC
Glow plug relay K4 coil over current
30 - FORM NO. 56043124 - Condor XL
Check Pump motor M8 wiring for problems (+ BLU and - BLU/RED).
Check pump motor for short circuit (spec XA) replace as needed. Test
current draw 12.5A full load max @12V.
Check H4 horn wiring for problems (+ ORN/GRN and - WHT/YEL). Check
horn for short circuit (spec 4A@12V) replace as needed.
Check optional back up alarm wiring for problems (+ ORN/GRN and
- BLU/BLK). Check horn for short circuit (spec .25A at 12V, electronic
alarm) replace as needed.
Check K1 relay coil wiring for problems (+ ORN/GRN and - BLU/GRN).
Check coil resistance; less than 36 ohms - replace. Also see main power
distribution electrical ladder detail. (Spec .29A@12V) replace as needed.
Control board has sensed open circuit fault for CB1 power for head/tail
and turn signal lamps. Check for GRA/RED wire shorted to ground.
Control board has sensed open circuit fault for CB2 power for mist pump
(M5) and (M8) wash hose pump. Check for Blue wire shorted to ground.
Control board has sensed open circuit fault for CB3 power for side broom
actuator motor (M7). Check for Violet wire shorted to ground.
Control board has sensed open circuit fault for CB4 power for hydrau-
lic solenoid manifold coils (L4-L 11). Check for Orange wire shorted to
ground.
Control board has sensed open circuit fault for CB5 power for hydraulic
solenoid manifold coils (L1, L2 and L3) also PumpsM4 and M6. Check for
GRN/BRN wire shorted to ground.
Check left turn signal wiring for problems (+ YEL and - BLK). Check lamp
for short (see the I/O table for circuit spec).
Check right turn signal wiring for problems (+ GRN and - BLK). Check
lamp for short (see the I/O table for circuit spec).
Check head and tail lamp wiring for problems (+ BRN, YEL/RED, ORN/
BLU and - BLK). Check lamps for short (see the I/O table for circuit spec).
Check left stop lamp wiring for problems (+ ORN/BRN and - BLK). Check
lamps for short (see the I/O table for circuit spec).
Same as left stop lamp just different wire color (+ YEL/RED and - BLK).
Check K4 relay coil wiring for problems (+ ORN/GRN and - WHT/ORN).
Check coil resistance; less than 36 ohms - replace. Also see diesel glow
plug starting circuit electrical ladder detail.
Troubleshooting Actions and Comments