Installation
CAUTION!
No service or maintenance should be performed until the technician has thoroughly read this service
manual. Except for routine cleaning and sanitizing, only qualified technicians should attempt to service
or maintain this equipment.
Countertop Installation
The E7 Series countertop model is designed to fit on counters underneath
standard mounted cabinets, this does not apply to E15 Series models . See
page 4
for dimensions . Installation instructions for freestanding model
may be found on
page
1 . A clearance of at least 7 .62 cm (3") is required behind and on
each side of the dispenser for electrical connection and ventilation
(Fig . 1) .
2 . Rough-in the electrical service and water line .
§ Electrical: 230V, single phase . The dispenser is provided with a 2 .4 m
(8 ft .) power cord with choice of CEE 7/7, AS 3112, or BS 1363 plug .
§ Water: supply line (with shut-off valve) connects to the dispenser's
1/4" MPT inlet .
NOTICE!
If installing optional Drip Tray Drain Kit or Leg Accessory,
complete those steps before proceeding. Refer to instructions
included with the Drip Tray Drain Kit, or see
Accessory instructions.
3 . Connect water line (Fig . 2 .1) .
4 . Connect to the 1/2" ID drain line (Fig . 2 .2) (barb fitting provided) and
route to customer drain . Drain line must slope 6 mm per 30,4 mm run
(1/4" per foot) .
5 . Connect power supply .
6 . Sanitize the dispenser prior to use (see Page 10) .
9 .
page 8
for Leg
Dispenser and Ice Machine 230 V/50 Hz, Rear Drain
Fig . 1
countertop models
minimum 77 mm (3")
clearance required
Fig . 2
1
Check valve must
be installed as
shown for proper
operation - note
direction of arrow.
2
7