(2) Wheel bearings

Lubricate and check wheel bearing adjustment every 800 hours or semi-annually. Use a good
quality automotive bearing lubricant grease ( Specification MIL-G-10924B or equivalent). Refer
also to TO-186 in Chapter 5 of this manual for additional information on trailer lubrication.
ITEM
Lube Oil
Lube Oil Filter
Fuel Oil Filter
Starter
Coolant
Air Cleaner
AC Generator

4. Air Cleaner Service

Refer to Section 1-1; Fig. 4. This air cleaner is a dry type which may be cleaned as many as six times be-
fore replacing it with a new air cleaner. A definite time schedule for cleaning or changing the air cleaner
cannot be determined because of varying operating conditions. However, since this air cleaner can be re-
moved and replaced without difficulty on this generator set (simply by loosening one metal clamp on each
end of the air cleaner) , it may be inspected either at prescribed service intervals or at any time deemed
necessary.
A. Inspecting the Air Cleaner
(1) Make periodic checks of air cleaner inlet screen for obstructions. If any obstructions are present,
remove them.
(2) Check outlet connection for proper seal.
NOTE : DO NOT judge the element's life just by looking at it, IT SHOULD LOOK DIRTY, or it's not
doing its job.
December 31/91 Revised
MAINTENANCE REQUIRED
Check oil level daily or after every 10 hours of use. Change oil after
200 hours or one month of use. Use heavy duty oil such as SAE-30
(MIL-L-2104D). Engine lube oil capacity: 18 quarts.
Change oil filter every 200 hours or 1 month of use.
Drain filter daily. Change filter element every 600 hours or 4 months of use.
Lubricate as needed, using heavy duty engine oil such as SAE-30
(MIL-L-2104B). Lubricate only when starter is removed from engine.
Check coolant level daily. Service and maintain coolant system according
to para.6. Engine coolant capacity: 20 quarts.
Check air cleaner periodically and clean or change it as necessary. (Refer
to Para. 4 for servicing instructions).
AC generator bearings are sealed and require no periodic lubrication.
Lubricationand Maintenance Chart
Figure 1
OM-2053
2-1
Page 3