Hobart 60PL20 Operation And Maintenance Manual page 35

Engine-driven generator set for truck or trailer mounting
Table of Contents

Advertisement

(a) Make certain the cooling system is adequately protected
WARNING: Make certain of adequate ventilation before starting the engine.
(b) Start the engine and operate at a fast idle (800 to 1000 RPM) until coolant temperature has
reached at least 140 deg F.
(c) Operate normal operating controls.
(2) If weekly operation is not possible, prepare and protect the engine in accordance with instructions
in the Perkins Diesel Operator's Manual.
(3) To protect the generator and other electrical components, the complete unit should be packaged,
using moisture proof packaging and sealing material. Place containers of moisture absorbing chemi-
cals, such as silica-gel, in the unit before packaging.
March 20/89
OM-2053
1-2