Troubleshooting Power Source Problems; Power Supply Unit Problems; Troubleshooting Cooling Problems - Dell DL1300 Owner's Manual

Table of Contents

Advertisement

Troubleshooting power source problems

1.
Press the power button to ensure that your system is turned on. If the power indicator does not glow
when the power button is pressed, press the power button firmly.
2.
Plug in another working power supply unit to ensure that the system board is not faulty.
3.
Ensure that no loose connections exist.
For example, loose power cables.
4.
Ensure that the power source meets applicable standards.
5.
Ensure that there are no short circuits.
6.
Have a qualified electrician check the line voltage to ensure that it meets the needed specifications.

Power supply unit problems

1.
Ensure that no loose connections exist.
For example, loose power cables.
2.
Ensure that the power supply unit (PSU) handle or LED indicates that the PSU is working properly.
For more information about PSU indicators, see the Power indicator codes section.
3.
If you have recently upgraded your system, ensure that the PSU has enough power to support the
new system.
4.
If you have a redundant PSU configuration, ensure that both the PSUs are of the same type and
wattage.
You may have to upgrade to a higher wattage PSU.
5.
Ensure that you use only PSUs with the Extended Power Performance (EPP) label on the back.
6.
Reseat the PSU.
NOTE: After installing a PSU, allow several seconds for the system to recognize the PSU and
determine if it is working properly.
If the problem persists, see the Getting help section.
Related Links
Getting help

Troubleshooting cooling problems

CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that are shipped with your product.
Ensure that the following conditions exist:
System cover, cooling shroud, EMI filler panel, memory module blank, or back filler bracket is not
removed.
Ambient temperature is not higher than the system specific ambient temperature.
External airflow is not obstructed.
A cooling fan is not removed or has not failed.
117

Advertisement

Table of Contents
loading

Table of Contents