Installation and Tapping –
Connecting the Keg Coupler
(when Supplied by Perlick)
Place one brown leather washer into black beer
line connector hose on hex nut side. Screw
connector to stainless steel beverage line on
faucet standard. Tighten with a wrench, but do
not over tighten.
Make sure lever handle on the keg coupler is in
the UP (untapped) position. Place one brown
leather washer into wing nut end of black beer
line connector hose and thread onto top of keg
coupler. Hand tighten.
Place clamp on one end of red air line. Push
end over air valve located inside cabinet.
Tighten clamp with screwdriver. Turn shut-off
valve to OFF (horizontal) position.
Place clamp on the other end of red air line and
push over tailpiece on coupler. Tighten clamp
with screwdriver.
CAUTION: Do not use keg coupler as a
handle to lift keg.
Tapping a Single Valve Keg
Single Valve Keg Coupler
Step 2
Be sure beer faucet is in closed position.
Align keg lugs with lug openings on bottom
of coupler.
1
Turn clockwise
turn. Pull handle out and
4
down. Keg is now tapped.
Open shut-off valve on air divider located inside
of the cabinet.
Important: Be sure to close this valve
when untapping keg.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
:
(Sankey)
Step 1
Step 3
Beer Dispensers
Connecting the Regulator to the
CO

Cylinder

2
Remove blue plug from regulator fitting.
(Note: Do not remove the carbonic washer).
Screw regulator onto gas cylinder valve. Tighten
with wrench until vertically straight. Be sure that
shut-off valve (black lever) on regulator is in
the OFF (horizontal) position.
Place a screw clamp over end of red air line
and push onto regulator tailpiece. Tighten clamp
with a screwdriver.
CO2
PRESSURE
GAUGE
FITTING FOR
RED AIR HOSE
SHUT-OFF VALVE
(BLACK LEVER IN
CLOSED POSITION)
Adjusting the CO
Turn regulator adjusting screw counterclockwise
until it turns freely.
Turn hand valve counterclockwise on CO
cylinder to the fully open position.
Turn regulator adjusting screw clockwise until
desired pressure is reached (approximately
12-15 lbs.). Tighten stop nut on adjusting screw.
Open shut-off valve on bottom of regulator.
6
REGULATOR
FITTING
30
20
40
PERLICK
10
50
PSI
60
0
REGULATOR
ADJUSTING
SCREW
Gas Flow
2
HAND
VALVE
CO2
GAS
DRUM
2