After the Memory IC (IC6004) or TV/VCR Main C.B.A. is replaced, be sure to set the
Default value to Memory IC as shown in "Memory IC Reference Table" below.
1. Press and hold STOP, PLAY, and VOL DOWN buttons on the unit together over 5
seconds with no cassette inserted.
The adjustment overlay will appear to Enter EVR Adjustment mode.
2. Set the Default value of all Control functions using a remote control as shown in
"Memory IC Reference Table."
Note:
For Selecting Control functions and setting Default value, refer to
ENTER EVR ADJUSTMENT
ADJUSTMENT
3. Press and hold STOP, PLAY, and VOL DOWN buttons on the unit together over 5
seconds again or press the POWER button OFF to release EVR Adjustment Mode.
The Default value will be written to Memory IC (IC6004).
4. Perform all EVR Adjustments. (Refer to
ADJUSTMENT WITH THE REMOTE
procedures.)
MODE" and
MODE" in ELECTRICAL ADJUSTMENT procedures.
Fig. 4-1
"HOW TO ENTER EVR PG SHIFTER
Fig. 4-2
"EVR (Electronic Variable Register)
CONTROL" in ELECTRICAL ADJUSTMENT