Holding Registers For Information Category C2 - Basler DECS-200 Instruction Manual

Digital excitation control system
Hide thumbs Also See for DECS-200:
Table of Contents

Advertisement

Registers
47048
5th character of the ASCII string of Boot program version number
6th character of the ASCII string of Boot program version number
47049
7th character of the ASCII string of Boot program version number
47050
47051
Last character of the ASCII string of Boot program version number
1st character of the ASCII string of date of the Boot program
47052
2nd character of the ASCII string of date of the Boot program
47053
47054
3rd character of the ASCII string of date of the Boot program
47055
4th character of the ASCII string of date of the Boot program
5th character of the ASCII string of date of the Boot program
47056
47057
6th character of the ASCII string of date of the Boot program
7th character of the ASCII string of date of the Boot program
47058
8th character of the ASCII string of date of the Boot program
47059
47060
Last character of the ASCII string of date of the Boot program
1st character of the ASCII string of style number information
47061
2nd character of the ASCII string of style number information
47062
47063
Last character of the ASCII string of style number information
Reserved for future C1 data
47064 to
47250

Holding Registers for Information Category C2

Registers
47251-52 Phase A to B rms generator voltage
47253-54 Phase B to C rms generator voltage
47255-56 Phase C to A rms generator voltage
47257-58 Average of the 3 rms line-to-line voltages
47259-60 Phase B generator current in amps
47261-62 Generator apparent power in kVA
47263-64 Generator real power in kW
47265-66 Generator reactive power in kvar
47267-68 Power factor
47269-70 Generator frequency in hertz
47271-72 Bus frequency in Hz
7-12
Table 7-11. Information Category C1 (Product Information)
Data Description
Table 7-12. Information Category C2 (Metering)
Data Description
Modbus™ Communication
Data
Access
Format
R-
UI8
R-
UI8
R-
UI8
R-
UI8
R-
UI8
R-
UI8
R-
UI8
R-
UI8
R-
UI8
R-
UI8
R-
UI8
R-
UI8
R-
UI8
R-
UI8
R-
UI8
R-
UI8
Not
Not
supported
defined
Data
Access
Format
R -
R32_23
R-
R32_23
R-
R32_23
R-
R32_23
R-
R32_23
R-
R32_23
R-
R32_23
R-
R32_23
R-
R32_23
R-
R32_23
R-
R32_23
DECS-200

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DECS-200 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents

Save PDF