For more convenience, this unit can also be controlled using an optional main wall control.
NOTES: 1.
The integrated control must be turned OFF to use an optional main control.
2. If an optional auxiliary control is used, if activated, this auxiliary control will override the optional main control.
Always disconnect the unit before making any connections. Failure in disconnecting power could result in electric shock or
damage of the wall control or electronic module inside the unit.
Never install more than one optional main wall control per unit. Make sure that the wires do not short-circuit between
themselves or by touching any other components on the wall control. Avoid poor wiring connections. To reduce electrical
interference (noise) potential, do not run wall control wiring next to control contactors or near light dimming circuits, electrical
motors, dwelling/building power or lighting wiring, or power distribution panel.
Use the terminal connector included in the installation kit to perform the electrical
connection for main and optional wall controls. Check if all wires are correctly inserted in
their corresponding holes in the terminal block. (A wire is correctly inserted when its orange
receptacle is lower than another one without wire. On illustration at right, wire A is correctly
inserted, but not wire B.)
3.2.1 E
C
LECTRICAL
ONNECTION TO
M
W
C
AIN
ALL
ONTROL
MODE
SET
SMART
PREF
VE0175
3.2.3 E
C
LECTRICAL
C
ONSTRUCTO OR
M
W
C
AIN
ALL

ONTROLS

NO C NC I OC OL Y R G B
Y
VE0325A
NOTE: On some older wall control models, the left
terminal is identified OC instead of Y; connect
this terminal to Y on terminal connector.
'
)
D
O
W
C
PTIONAL
ALL
ONTROLS
A
LTITUDE
NO C NC I OC OL Y R G B
L
-T
ONNECTION
TO
ITE
OUCH
S
-T
C
IMPLE
OUCH
ONSTRUCTO
MAIN WALL CONTROL
LITE-TOUCH CONSTRUCTO
and
SIMPLE-TOUCH CONSTRUCTO
REAR VIEW
G
B
G B
Y
!
WARNING
CAUTION
3.2.2 E
VE0250
3.2.4 E
NO C NC I OC OL Y R G B
VE0102
11
B
VE0272
C
LECTRICAL
ONNECTION TO
M
W
C
AIN
ALL
ONTROL
NO C NC I OC OL Y R G B
C
LECTRICAL
ONNECTION TO
M
W
C
AIN
ALL
ONTROL
A
D
-T
ECO
OUCH
C
ONSTRUCTO
5°C
41°F
OFF MIN MAX
-
-5°C
23°F
-20°C
-4°F
CONSTRUCTO

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

415004150641504

Table of Contents