Electrical Connection To Optional Wall Controls; Altitude Or Platinum; Deco-Touch; Lite-Touch Constructo, Simple-Touch Constructo, Lite-Touch Bronze Or Simple-Touch Bronze - Venmar 41502 User's And Installer's Manual

Top ports units; side ports units
Hide thumbs Also See for 41502:
Table of Contents

Advertisement

For the Installer
6.2 E
C
LECTRICAL
ONNECTION TO
Use the chart below to verify compatibility with the optional controls before making any connection.
C
1.0 HRV
ONSTRUCTO
C
1.0 ERV
ONSTRUCTO
C12 HRV
C12 ERV
60H HRV
60H ERV
60H+ HRV
60H+ ERV
Always disconnect the unit before making any connections. Failure in disconnecting power could result in electrical
shock or damage of the wall control or electronic module inside the unit.
Never install more than one optional main wall control per unit. Make sure that the wires do not short-circuit
between themselves or by touching any other components on the wall control. Avoid poor wiring connections. To
reduce electrical interference (noise) potential, do not run wall control wiring next to control contactors or near
light dimming circuits, electrical motors, dwelling/building power or lighting wiring, or power distribution panel.
Use the terminal connector included in the installation kit to perform the electrical connection for main
and optional wall controls.
Make sure all wires are correctly inserted in their corresponding holes in the terminal block. A wire is
correctly inserted when its orange receptacle is lower than another one without wire. On the picture
below, wire A is correctly inserted, but wire B is not.
Once the connections have been made, insert the terminal connector in the recessed side of the
electrical compartment.
6.2.1 A
P
LTITUDE OR
LATINUM
NO C NC I OC OL Y R G B
MODE
SET
SMART
PREF
VE0181
6.2.3 L
-T
C
ITE
OUCH
ONSTRUCTO
L
-T
B
S
ITE
OUCH
RONZE OR
IMPLE
NO C NC I OC OL Y R G B
G B
Y
VE0328A
6.2.5 O
A
C
PTIONAL
UXILIARY
NO C NC I OC OL Y R G B
VE0089A
O
W
C
PTIONAL
ALL
ONTROLS
Altitude

Deco-Touch

Lite-Touch Constructo
Platinum
Deco-Touch
Lite-Touch Bronze
, S
-T
C
IMPLE
OUCH
ONSTRUCTO
-T
B
OUCH
RONZE
Y
G
B
ONTROLS
DEHUMIDISTAT
20/40/60-MINUTE or 20-MINUTE
60-MINUTE
PUSH-BUTTON SWITCHES
CRANK TIMER
Main Controls
Simple-Touch Constructo
Constructo
Simple-Touch Bronze
Bronze
WARNING
CAUTION
6.2.2 D
-T
ECO
VE0250
,
6.2.4 C
ONSTRUCTO OR
NO C NC I OC OL Y R G B
VE0323
(5 MAXIMUM)
11
Auxiliary Controls
Dehumidistat
20/40/60-minute push-button timer
20-minute lighted push-button
60-minute crank timer
VE0272
OUCH
NO C NC I OC OL Y R G B
B
RONZE
5°C
41°F
OFF MIN MAX
-
-5°C
23°F
-20°C
-4°F
B
A