1.5. Filter stage (E):
Except for the filter cartridge, the activated charcoal filter 264 is identical in construction to the filter stage (B). The
activated charcoal cartridge, art. # 85373 is integrated in the filter. Please ensure that the activated charcoal filter is
always directly installed behind the condensate separator and the fine filter stage.
1.6. Filter Carttridges
Typ:
Sinter fi lter cartridge
Sinterd bronze 5 μm,
surface area 100 cm², solvent
regenerable
Replacement interval every
six months
Art. No. 22160
In case of extreme contamination, fi lters should be checked and, if necessary, replaced more frequently. The sintered bronze fi lter
and the fi lter housing tube (5, 8) must be cleaned every six months at the latest, if necessary, replace sintered bronze fi lter cartridge.
Saturated fi lter cartridges bear the danger of functional defaults during painting resp. affecting the painter's health while using sup-
plied-air respirator systems.
2. Technical Data And Specifications
Air inlet G 1/2 inside thread
10 bars/145 psi Maximum inlet operating pressure
10 bars/145 psi Maximum outlet operating pressure
Air flow rated at > 2000 Nl/min (72 cfm) at 6 bars/90 psi (see graph)
Max. surrounding temperature 120° C, with activated charcoal max. 60° C
Weight:
SATA filter
244 = 4,3 kg
264 = 1,3 kg
284 = 5,6 kg
3. Mounting The Unit
Using the included holding angles (10), the filter must be firmly mounted in the vertical position at the two mounting
holes. Ensure that the unit is mounted in a manner to protect against outside mechanical influence such as bumping
or shaking. The filter may also be mounted vertically and firmly to compressed air lines without mounting to the wall
(Mount air lines accordingly).
Screw in fitting (no. 4). Ensure tight fit and tension free assembly. For maintenance, it is recommended to include shut-
off valve with removable coupling at the air inlet (a coupling may also be put at the air outlet).
Connect one end of the condensate drain hose (no. 7) on the brass connection piece and the other end into an appro-
priate condensate storage container. Make sure that the container will not tip and the hose will not jump out when
condensate is blown.
ATTENTION! Condensate is hazardous waste.
Operating instructions SATA filter 200
Fine fi lter cartridge, Poly-
propylene Micro Fibre layer
Surface area 300 cm² Filtering
capacity 0,01 μm 99,998 %
separation, non-regenerable
Replacement interval every
six months, at the latest when
the maximum pressure diffe-
rence between inlet and outlet
pressure is 1 bar/14.5 psi
Art. No. 81810
Activated charcoal cartridge
non-regenerable
Replacement interval every
three months
Art. No. 85373