  • Page 1 Ez One Shot UNIVERSAL USER’S MANUAL Version: 2015.1...
  • Page 2: Table Of Contents

    CONTENTS PREFACE Table of Contents............LED & Beeper Indication..........Cloning Mode............How to fix the scanner to the terminal....... How to change a cable..........How to set up the parameter........GENERAL SETTINGS (GROUP 1 - 12) Default, Abort, Check Version, Setup Code Read..Reading Mode ............
  • Page 3 CONTENTS SYMBOLOGIES (GROUP 34 - 51) 34~36 Enable/Disable Barcode Symbology..43-45 China postcode(Toshiba code)....... 37 MSI code, UK Plessey code........47 Code 93, Telepen, IATA.......... Interleaved 2 of 5, Code 11........51 Industrial 2 of 5, Matrix 2 of 5......... 41 Codabar..............55 ABC Codabar, CX Codabar........
  • Page 4: Led & Beeper Indication

    LED & BEEPER INDICATION Status Blue/Green LED Red LED Beeper Remark Initializing/ Solid for 2 sec 1 long beep Power-up Successful Barcode 1 Flash 1 beep Scan Successful 2 Flashes 2 beeps Connection Reads 2 beeps Configuration Barcode Data See Batch Mode Temporarily/ 2 short beeps 1 Flash...
  • Page 5: Cloning Mode

    CLONING MODE WHAT IS CLONING MODE? CLONING duplicates a scanners settings in other scanners. It can save time when a number of scanners must be programmed to the same settings. HOW SHOULD CLONING WORK? 1. Using this guide, make all the necessary settings for one wand. 2.
  • Page 6: Cloning Mode

    CLONING MODE EXAMPLE : 1. PROJECT ASSIGNMENTS: 1.1. Beep tone: BEEP LOW -- HIGH. 1.2. Capslock Mode: CAPSLOCK ON. 1.3. Reading Mode: CONTINUOUS AUTO OFF. 2. SETTING PROCEDURE: 2.1. Scan BEEP LOW -- HIGH (GROUP 3). 2.2. Scan CAPSLOCK ON (GROUP 12). 2.3.
  • Page 7: How To Fix The Scanner To The Terminal

    HOW TO CONNECT THE SCANNER TO THE HOST TERMINAL: Handheld Barcode Scanner KEYBOARD WEDGE INTERFACE 1. Power down the host computer. 2. Disconnect the keyboard cable from the computer. 3. Connect the “Y ” cable between the keyboard and the scanner and computer. 4.
  • Page 8: How To Change A Cable

    USB INTERFACE The USB Interface supported is compatible with Apple MAC series, , Windows 98, 2000, XP, Vista, 7, 8 and so on. 1. Connect the USB cable between the scanner and the computer. 2. The scanner will beep. 3. The scanner will detect the USB driver automatically. (The first time the scanner is connected via the USB port, follow the appropriate instructions for the host computer.) 4.
  • Page 9: How To Set Up The Parameter

    HOW TO SET PARAMETERS How do you program a scanner with this user’s guide? 1. Use the scanner to scan at the bar code representing the function/ parameter you want to set. 2. When you hear two beeps, the new settings have been defined or updated into the memory processor.
  • Page 10: General Settings (Group 1 - 12)

    GROUP-1 GENERAL SETTINGS . A001$ DEFAULT *Reset to factory default . A007$ CHECK VERSION *Check firmware version . P023$ RESET/ ABORT *Abort multi-step configuration SETUP CODE ON SETUP CODE READ SETUP CODE OFF *Caution: Scanning SETUP CODE OFF will turn the scanner into unprogrammable state and the scanner will not react to any configuration barcode!
  • Page 11: Reading Mode

    GROUP-2 GENERAL SETTINGS - READING MODE . F005$ LED is always on. The trigger does not function in Continuous Mode. CONTINUOUS MODE . F001$ The LED is on steady if a bar code is close to the scanner, but starts flashing if no bar code is detected after 60 FLASH MODE seconds.
  • Page 12: Beep Tone, Terminator

    GROUP-3 GENERAL SETTINGS 2.1KHz Buzzer BEEP TONE (Tethered Scanner) 2.7KHz Buzzer . F012$ (Wireless Scanner) .F019$ BEEP OFF . F014$ BEEP HIGH .F021$ BEEP HIGH . F016$ BEEP HIGH--LOW .F018$ BEEP HIGH--LOW . F013$ BEEP MEDIUM .F020$ BEEP MEDIUM . F015$ BEEP LOW--HIGH .F022$ BEEP LOW--HIGH...
  • Page 13: Send Data Length, Preamble, Postamble

    GROUP-4 SEND DATA LENGTH, PREAMBLE & POSTAMBLE. SEND DATA LENGTH .D019$ SEND DATA LENGTH ON .D020$ SEND DATA LENGTH OFF PREAMBLE & POSTAMBLE ( PREFIX AND SUFFIX ) . A011$ CLEAR PRE/ POSTAMBLE . A012$ PREAMBLE (16) . A013$ POSTAMBLE (16) EXAMPLE: Set PREAMBLE String as “...
  • Page 14: Accuracy Adjustment

    GROUP-5 GENERAL SETTINGS - ACCURACY ADJUSTMENT . A010$ ACCURACY ADJUSTMENT Accuracy Adjustment assures a more reliable decoded output. Enabling the feature and setting a number from 1 to 9 subjects the decoded output a higher standard of accuracy. The higher the number, the greater the accuracy.
  • Page 15: Code Id, Inverse Barcode

    GROUP-6 GENERAL SETTINGS ENABLE INVERSE BARCODE .D021$ DISABLE INVERSE BARCODE [READS POSITIVE BARCODE ONLY] .D022$ ENABLE INVERSE BARCODE [READS POSITIVE & NEGATIVE BARCODES] ENABLE CODE ID .A008$ FACTORY ID ON .A014$ AIM ID ON .A015$ SET ID ON DISABLE CODE ID .A009$ NOTES: 1.
  • Page 16: Symbologies Code Identifier

    GROUP-7 GENERAL SETTINGS SYMBOLOGIES CODE ID IDENTIFIER AIM ID Factory Factory AIM ID Symbologies Symbologies (new) (new) EAN 128 MSI(MOD 10 / CDV & not send CD) Code 128 Code 32 EAN8(+2/+5 OFF) EAN8(+2 ON) Codabar EAN8(+5 ON) Codabar(ABC Codabar) Codabar(CDV &...
  • Page 17: 8~9 Set Code Id

    GROUP-8 GENERAL SETTINGS - SET CODE ID . P001$ EAN 13 Set ID . P002$ EAN 8 Set ID . P003$ UPC E Set ID . P004$ UPC A Set ID . P005$ Code 39 Set ID . P013$ Code 93 Set ID .
  • Page 18 GROUP-9 GENERAL SETTINGS - SET CODE ID . P014$ MSI Code Set ID . P015$ UK Plessey Set ID . P017$ Matrix 2 of 5 Set ID . P006$ Interleaved 2 of 5 Set ID . P018$ Industrial 2 of 5 Set ID .
  • Page 19: Inter-Block And Inter-Character Delay

    GROUP-10 GENERAL SETTINGS INTERBLOCK DELAY 10mS 50mS 100mS 200mS 500mS INTERCHARACTER DELAY 140uS 500uS 16mS...
  • Page 20: Keyboard Layout

    GROUP-11 GENERAL SETTINGS KEYBOARD LAYOUT . C009$ . C010$ JAPAN (106 key) . C025$ ENGLISH (USA) . C018$ CANADIAN (FRENCH) . C034$ ENGLISH (UK) . C012$ CANADIAN (TRADITIONAL) . C029$ FRENCH . C011$ NORWEGIAN . C026$ GERMAN . C014$ SWEDISH .
  • Page 21: Caplock Mode, Numeric Key

    GROUP-12 GENERAL SETTINGS . A005$ CAPITAL LOCK MODE CAPLOCK OFF . A004$ . A006$ CAPLOCK ON CAPLOCK FREE NOTE: 1. When barcode scanner is set to Caplock Free mode, no matter keyboard Capslock LED indicator is ON or OFF, output will be always the same as the Original barcode.
  • Page 22: Tethered Scanner Settings (Group 13 - 19)

    GROUP-13 TETHERED SCANNER SETTINGS . C004$ PC-AT COMPUTER TYPE . C007$ NOTEBOOK* SYMPTOMS SOLUTION Scanner seems to be 1. Unplug the cable from the host computer. performing as usual, 2. Plug the cable back into the host computer. but no data is being 3.
  • Page 23: Bi-Color Setting

    GROUP-14 TETHERED SCANNER SETTINGS (The following are only supported by Bi-Color models) BI-COLOR: CYCLE MODE . D027$ *.D027$* GREEN > RED . D028$ *.D028$* RED > GREEN . D029$ *.D029$* GREEN > BI-COLOR . D030$ *.D030$* RED > BI-COLOR 1. Illumination color will switch back and forth from one to another when good read does not occur.
  • Page 24: Advanced Autosensing Setting

    GROUP-15 ADVANCED AUTO-SENSING SETTINGS (The following is only supported by autosensing models) MAGNETIC SWITCH . F034$ (CCD & LASER SCANNERS) MAGNETIC SWITCH ON . F035$ MAGNETIC SWITCH OFF NOTES: 1. The Magnetic Switch is automatically activated when Auto- Sensing Mode is on. 2.
  • Page 25: Advanced Autosensing And Idle Mode Setting

    GROUP-16 ADVANCED AUTO-SENSING SETTINGS (The following is only supported by autosensing models) DEACTIVATION TIME . F030$ (CCD & LASER SCANNERS) DEACTIVATION TIME NOTES: 1. The default of Deactivation Time is 3 Sec. 2. Deactivation Time is the time interval between the last scan and the automatic deactivation of LED or Laser light in Auto-Sensing Mode.
  • Page 26: Rs232 - Baud Rate, Data Bits, Parity

    GROUP-17 TETHERED SCANNER - RS232 SETTINGS . E005$ BAUD RATE . E001$ 4800 . E006$ . E002$ 9600 . E007$ . E003$ 19200 . E022$ 1200 . E004$ 38400 2400 . E012$ DATA BITS & PARITY . E008$ 8 Bits SPACE .
  • Page 27: Flow Control, Bcc

    GROUP-18 TETHERED SCANNER - RS232 SETTINGS . E016$ STOP BITS 1 STOP BIT . E017$ 2 STOP BITS . E018$ HANDSHAKING NONE . E019$ RTS enable at Power on . E020$ RTS enable with Communication . E023$ ACK / NAK .
  • Page 28: Wand Emulation

    GROUP-19 TETHERED SCANNER - WAND EMULATION SETTINGS . D001$ LEVEL DURATION OF MINI WIDTH 200us . D002$ 600uS . D003$ POLARITY OF IDLE CONDITION . D004$ HIGH . D005$ OUTPUT OF WAND EMULATION Bar High / Space Low . D006$ Bar Low / Space High .
  • Page 29: Wireless Scanner Settings (Group 20 - 33)

    GROUP-20 WIRELESS SCANNER SETTINGS INTERFACE . E043$ *.E043$* BT HID Emulates a Bluetooth HID keyboard that transmits each barcode data to the host after decode. . E042$ *.E042$* BT SPP Emulates a Bluetooth SPP device that transmits each barcode data in serial communication to the host after decode.
  • Page 30: Bluetooth Profile

    GROUP-21 WIRELESS SCANNER SETTINGS BLUETOOTH PROFILE . E043$ (Recommanded) BT mode - HID 1. Press the trigger for 1 second to activate the scanner. 2. Scan [DISCONNECT] 3. Scan [BT mode - HID]; the scanner will emit several beeps. 4. Select “Wireless Scanner” from discovered device list. (For PC, please click “Create a pairing code for me”) 5.
  • Page 31: Pincode Setup

    GROUP-22 WIRELESS SCANNER SETTINGS PINCODE SETUP STEP 1 . E032$ Pincode Start STEP 2 (see below) Scan numeric barcodes NUMERIC BARCODES based on the pincode generated by the Bluetooth application. NUMERIC BARCODES STEP 3 Enter . E033$ STEP 4 Pincode Stop...
  • Page 32: Getting Connected - Ios & Android

    GROUP-23 WIRELESS SCANNER SETTINGS Getting Connected - iOS (Apple) (Group 21), Simply follow instruction in [BT mode - HID]. in which step 5 & 6 can be skipped since Apple devices will not require pincode for connection. Touch Keyboard . E047$ ENABLE iOS HOTKEY .
  • Page 33: Power Off Timeout

    GROUP-24 WIRELESS SCANNER SETTINGS POWER OFF TIMEOUT Variable Timeout . B030$ *.B030$* SET MINUTE (Range: 00 ~ 60) . B029$ *.B029$* SET SECOND (Range: 00 ~ 60) The timeout is 3 minutes by default, and is programmable to the second and minute, ranging from 10 seconds (00:10) to 60 minutes and 60 seconds (60:60) For example, to set the timeout as 5 minutes 30 seconds: 1.
  • Page 34: Set Bluetooth Device Id

    GROUP-25 WIRELESS SCANNER SETTINGS SET BLUETOOTH DEVICE ID To customize your own Bluetooth device name for the wireless scanner, please follow below steps: STEP 1 . B022$ Default Wireless ID STEP 2 . B023$ Set Wireless ID STEP 3 Scan up to 16 alphanumeric characters from Full ASCII Table (GROUP 52-60) as your desired ID name.
  • Page 35: Set Spp Pincode

    GROUP-26 WIRELESS SCANNER SETTINGS SET SPP PINCODE By default, the pincode under SPP profile for the scanner is “1234”. You may customize this pincode with below steps: STEP 1 . B024$ Set SPP Pincode STEP 2 (see below) Scan numeric barcodes NUMERIC BARCODES Up to 8 numbers can be set as SPP pincode.
  • Page 36: Spp Master Mode

    GROUP-27 WIRELESS SCANNER SETTINGS SPP MASTER MODE First, please generate one configuration barcode for the target SPP slave device in below methods: 1. The barcode must be Code 39 with no checksum 2. Barcode data format: LTB + Target MAC address For example, the target SPP slave device’s MAC address is 001583522C3B.
  • Page 37: Spp Remote Control, Shut Down, Disconnection

    GROUP-28 WIRELESS SCANNER SETTINGS SPP REMOTE CONTROL There are two ways to verify connection status by the host under SPP profile. Command Response Host sends: CR,LF,{,A,L,},CR,LF (8 bytes) Scanner replys: O,K,CR,LF (4 bytes) Beeper Response Host sends: CR,LF,{,M,1,},CR,LF (8 bytes) Scanner reacts: a short beep SHUT DOWN...
  • Page 38: Batch Mode, Binary Check Character

    GROUP-29 WIRELESS SCANNER SETTINGS BATCH MODE . E054$ ENABLE . E053$ DISABLE When out of range, the scanner will temporarily keep scanned data in its memory buffer(2K RAM) until the buffer is full. When back in range, the scanner will send all stored data back to the host. *Note: 1.
  • Page 39: Memory Mode - Memory Mode, Delete Record

    GROUP-30 WIRELESS SCANNER SETTINGS MEMORY MODE For memory version only . C035$ *.c035$* MEMORY MODE After scanning the above barcode, the scanner will be able to collect barcode data off-line. The barcode data will be stored in the format of: <...
  • Page 40: Data Format

    GROUP-31 WIRELESS SCANNER SETTINGS DATA FORMAT For memory version only . R011$ *.R011$* DATA FORMAT The default Data Format is <Date>, <Time>, <Barcode Data> below are items and their setup codes: Code Item Code Item Date Barcode Data Time Quantity Example: To change Data Format to <Barcode Data>, <Date>, <Time>...
  • Page 41: Memory Mode - Data Format, Date & Time Setup. 40 32 Memory Mode - Date Format, Time Format

    GROUP-32 WIRELESS SCANNER SETTINGS DATE FORMAT For memory version only . R008$ *.R008$* DATE FORMAT The default Date Format is DD/MM/YYYY (Code = 09), below is full list of available formats and their setup codes: Code Format Code Format DD-MM-YYYY DD/MM/YYYY MM-DD-YYYY MM/DD/YYYY...
  • Page 42: Memory Mode - Quantity

    GROUP-33 WIRELESS SCANNER SETTINGS QUANTITY For memory version only . R017$ *.R017$* ENABLE QUANTITY INPUT Once you enable quantity input, the operation procedure under memory mode will be as follows: 1. Scan [MEMORY MODE] (Group 30) 2. Set DATA FORMAT (Group 31) as appropriate. For example, your data format is <Barcode Data>, <Quantity>.
  • Page 43: Symbologies (Group 34 - 51) 34~36 Enable/Disable Barcode Symbology

    GROUP-34 ENABLE/ DISABLE SYMBOLOGIES ENABLE DISABLE . A002$ . A003$ ENABLE ALL CODE . K010$ DISABLE ALL CODE . K011$ CODE 32 . K001$ CODE 32 . K002$ CHINA POSTAL CODE . L010$ CHINA POSTAL CODE . L011$ UK PLESSEY CODE .
  • Page 44 GROUP-35 ENABLE/ DISABLE SYMBOLOGIES ENABLE DISABLE . H001$ . H002$ UPC-A . H007$ UPC-A . H008$ UPC-E . H019$ UPC-E . H020$ EAN-8 . H013$ EAN-8 . H014$ EAN-13 . L001$ EAN-13 . L002$ . G008$ . G009$ CODE 39 .
  • Page 45: China Postcode(Toshiba Code)

    GROUP-36 ENABLE/DISABLE SYMBOLOGIES, CHINA POSTAL CODE ENABLE . N032$ DISABLE . N033$ GS1 Databar ENABLE GS1 Databar DISABLE . N038$ . N039$ GS1 Databar STACKED ENABLE GS1 Databar STACKED DISABLE . N010$ GS1 Databar LIMITED ENABLE . N011$ GS1 Databar LIMITED DISABLE .
  • Page 46 APPENDIX FULL ASCII ( Code 39 ) NUMERIC TABLE SETTING PROCEDURE MIN / MAX LENGTH STEP 1 - Scan: MIN LENGTH/ MAX LENGTH STEP 2 - Scan: Two digits from Appendix. STEP 3 - Scan: MIN LENGTH/ MAX LENGTH Please note that when Min Length and / or Max Length are enabled, the scanner will only read bar codes that fall into those length parameters.
  • Page 47: Msi Code, Uk Plessey Code

    GROUP-37 SYMBOLOGIES: MSI CODE, UK PLESSEY CODE . L001$ . L008$ ENABLE CHECK DIGIT DOUBLE 11 . L002$ PLUS MOD 10 . L009$ DISABLE CHECK DIGIT SINGLE . L004$ MOD 10 . L005$ CDV & SEND CD MIN LENGTH [ 6 ] .
  • Page 48 APPENDIX FULL ASCII ( Code 39 ) NUMERIC TABLE SETTING PROCEDURE MIN / MAX LENGTH STEP 1 - Scan: MIN LENGTH/ MAX LENGTH STEP 2 - Scan: Two digits from Appendix. STEP 3 - Scan: MIN LENGTH/ MAX LENGTH Please note that when Min Length and / or Max Length are enabled, the scanner will only read bar codes that fall into those length parameters.
  • Page 49: Code 93, Telepen, Iata

    GROUP-38 SYMBOLOGIES: CODE 93, TELEPEN, IATA . G010$ CODE 93 . G012$ ENABLE . G011$ MIN LENGTH [ 6 ] . G013$ DISABLE MAX LENGTH [ 48 ] . L014$ TELEPEN . L020$ ENABLE TELEPEN TELEPEN ASCII . L015$ . L021$ DISABLE TELEPEN TELEPEN NUMBER .
  • Page 50 APPENDIX FULL ASCII ( Code 39 ) NUMERIC TABLE SETTING PROCEDURE MIN / MAX LENGTH STEP 1 - Scan: MIN LENGTH/ MAX LENGTH STEP 2 - Scan: Two digits from Appendix. STEP 3 - Scan: MIN LENGTH/ MAX LENGTH Please note that when Min Length and / or Max Length are enabled, the scanner will only read bar codes that fall into those length parameters.
  • Page 51: Interleaved 2 Of 5, Code 11

    GROUP-39 SYMBOLOGIES: INTERLEAVED 2 OF 5, CODE 11 . J001$ INTERLEAVED 2 OF 5 . J008$ ENABLE . J002$ First digit suppressed . J009$ DISABLE . J003$ Last digit suppressed . J014$ DISABLE CDV . J004$ NO suppressed . J006$ CDV &...
  • Page 52 APPENDIX FULL ASCII ( Code 39 ) NUMERIC TABLE SETTING PROCEDURE MIN / MAX LENGTH STEP 1 - Scan: MIN LENGTH/ MAX LENGTH STEP 2 - Scan: Two digits from Appendix. STEP 3 - Scan: MIN LENGTH/ MAX LENGTH Please note that when Min Length and / or Max Length are enabled, the scanner will only read bar codes that fall into those length parameters.
  • Page 53: Industrial 2 Of 5, Matrix 2 Of 5

    GROUP-40 SYMBOLOGIES: INDUSTRIAL 2 OF 5, MATRIX 2 OF 5 INDUSTRIAL 2 OF 5 . N001$ . N005$ ENABLE . N002$ CDV & NOT SEND CD DISABLE . N006$ . N003$ MIN LENGTH [ 6 ] DISABLE CDV . N007$ .
  • Page 54 APPENDIX FULL ASCII ( Code 39 ) NUMERIC TABLE SETTING PROCEDURE MIN / MAX LENGTH STEP 1 - Scan: MIN LENGTH/ MAX LENGTH STEP 2 - Scan: Two digits from Appendix. STEP 3 - Scan: MIN LENGTH/ MAX LENGTH Please note that when Min Length and / or Max Length are enabled, the scanner will only read bar codes that fall into those length parameters.
  • Page 55: Codabar

    GROUP-41 SYMBOLOGIES: CODABAR . I 001$ CODABAR ENABLE . I 007$ . I 002$ CDV & NOT SEND CD . I 008$ DISABLE . I 005$ MIN LENGTH [ 6 ] . I 009$ DISABLE CDV . I 006$ MAX LENGTH [ 48 ] CDV &...
  • Page 56 APPENDIX FULL ASCII ( Code 39 ) NUMERIC TABLE SETTING PROCEDURE MIN / MAX LENGTH STEP 1 - Scan: MIN LENGTH/ MAX LENGTH STEP 2 - Scan: Two digits from Appendix. STEP 3 - Scan: MIN LENGTH/ MAX LENGTH Please note that when Min Length and / or Max Length are enabled, the scanner will only read bar codes that fall into those length parameters.
  • Page 57: Abc Codabar, Cx Codabar

    GROUP-42 SYMBOLOGIES: ABC- CODABAR, CX- CODABAR . I 017$ ABC- CODABAR . I 039$ . I 018$ INSERT DATA- ON . I 036$ . I 035$ INSERT DATA- OFF SET INSERT DATA* The data can be any alphanumerics of FULL ASCII Table (GROUP 52-60) ABC-CODABAR (American Blood Commission).
  • Page 58: Codabar Coupling

    GROUP-43 SYMBOLOGIES: CODABAR COUPLING, ADJACENT REQUIRED CODABAR COUPLING . I 019$ . I 041$ . I 020$ INSERT DATA - ON . I 026$ . I 021$ INSERT DATA - OFF SET INSERT DATA* ABC-Codabar and CX-Codabar have certain rules regarding the Stop Character of first bar code and the stop character of second bar code while in conjunction, while Codabar- Coupling is enabled, the data from any two Codabar bar codes...
  • Page 59: Code 39 (Full Ascii/Standard), Code 32

    GROUP-44 SYMBOLOGIES: STANDARD & FULL ASCII CODE 39, CODE 32 STANDARD CODE 39 . G003$ & FULL ASCII 39 DISABLE CDV . G008$ . G004$ ENABLE . G009$ CDV & SEND CD . G005$ DISABLE . G001$ CDV & NOT SEND CD .
  • Page 60 APPENDIX FULL ASCII ( Code 39 ) NUMERIC TABLE SETTING PROCEDURE MIN / MAX LENGTH STEP 1 - Scan: MIN LENGTH/ MAX LENGTH STEP 2 - Scan: Two digits from Appendix. STEP 3 - Scan: MIN LENGTH/ MAX LENGTH Please note that when Min Length and / or Max Length are enabled, the scanner will only read bar codes that fall into those length parameters.
  • Page 61: Upc-E

    GROUP-45 SYMBOLOGIES FORMATTING: UPC-E . H007$ UPC-E ENABLE . H010$ . H008$ LEAD DIGIT NO SEND . H011$ DISABLE . H009$ CHECK DIGIT SEND LEAD DIGIT SEND . H012$ CHECK DIGIT NO SEND . H037$ ADD ON SUPPLEMENT +5 ON .
  • Page 62: Upc-E(0)&(1), Upc-E Expand

    GROUP-46 SYMBOLOGIES: UPC-E SYSTEM NUMBER . H064$ UPC-E0 E [ 0 ] OFF . H063$ E ( 0 ) ON . H065$ UPC-E1 E [ 1 ] ON . H066$ E ( 1 ) OFF NOTE: Most UPC bar codes lead with 0 number systems, for these bar codes use UPC E(0) selection.
  • Page 63: Upc-A

    GROUP-47 SYMBOLOGIES FORMATTING: UPC- A . H001$ UPC- A . H004$ ENABLE . H002$ LEAD DIGIT NO SEND DISABLE . H005$ . H003$ CHECK DIGIT SEND LEAD DIGIT SEND . H006$ CHECK DIGIT NO SEND . H068$ UPC-A EXPAND TO EAN-13 ENABLE .
  • Page 64: Ean-8

    GROUP-48 SYMBOLOGIES FORMATTING: EAN 8 . H019$ EAN-8 . H022$ ENABLE . H020$ LEAD DIGIT NO SEND . H023$ DISABLE . H021$ CHECK DIGIT SEND . H024$ LEAD DIGIT SEND CHECK DIGIT NO SEND . H029$ ADD ON SUPPLEMENT . H043$ + 5 ON ADD A SPACE ON .
  • Page 65: Ean-13, Issn, Isbn, Ismn

    GROUP-49 SYMBOLOGIES FORMATTING: EAN13, ISBN, ISSN, ISMN . H013$ EAN-13 . H016$ ENABLE . H014$ LEAD DIGIT NO SEND . H017$ DISABLE . H015$ CHECK DIGIT SEND . H018$ LEAD DIGIT SEND CHECK DIGIT NO SEND . H025$ ADD ON SUPPLEMENT .
  • Page 66: Ean/Ucc 128, Code 128, Pdf417

    GROUP-50 SYMBOLOGIES: EAN/UCC-128, CODE 128 . M001$ EAN/ UCC-128 . M005$ ENABLE . M002$ FUNC 1 CHAR SEND . M006$ DISABLE . M003$ FUNC 1 CHAR NOT SEND CODE ID ENABLE . M007$ . M004$ DEFINE EAN 128 CODE ID DISABLE NOTES: DEFINE EAN 128 The first FNC1 character is translated to ]c1, and the second FNC1 character is translated to an ASCII <GS>...
  • Page 67: Databar(Rss) Stacked, Limited, Expanded

    GROUP-51 GS1 DataBar, LIMITED, EXPANDED GS1 DataBar (RSS) - OMNI & STACKED . N032$ . N033$ GS1 DataBar ENABLE . N034$ GS1 DataBar DISABLE . N035$ GS1 DataBar CHECK DIGIT SEND . N036$ GS1 DataBar CHECK DIGIT NOT SEND . N037$ GS1 DataBar PREFIX SEND .
  • Page 68: Full Ascii Table(Code 39)

    GROUP-52 FULL ASCII TABLE ( CODE 39 ) CONTROL CODES...
  • Page 69 GROUP-53 FULL ASCII TABLE ( CODE 39 ) CONTROL CODES...
  • Page 70 GROUP-54 FULL ASCII TABLE ( CODE 39 ) SYMBOLS...
  • Page 71 GROUP-55 FULL ASCII TABLE ( CODE 39 ) SYMBOLS >...
  • Page 72 GROUP-56 FULL ASCII TABLE ( CODE 39 ) UPPER CASE ALPHABETS...
  • Page 73 GROUP-57 FULL ASCII TABLE ( CODE 39 ) UPPER CASE ALPHABETS...
  • Page 74 GROUP-58 FULL ASCII TABLE ( CODE 39 ) LOWER CASE ALPHABETS...
  • Page 75 GROUP-59 FULL ASCII TABLE ( CODE 39 ) LOWER CASE ALPHABETS...
  • Page 76 GROUP-60 FULL ASCII TABLE ( CODE 39 ) NUMBERS...
  • Page 77: 63 Function Key Table(Code 39) For Pc-At

    GROUP-61 FULL ASCII TABLE ( CODE 39 ) FUNCTION KEYS Home $T+D Enter (Numeric Key) $T+O...
  • Page 78 GROUP-62 FULL ASCII TABLE ( CODE 39 ) NAVIGATION KEYS Cursor Right Cursor Left Cursor Up Cursor Down Page Up Page Down Back Tab Enter $T%K...
  • Page 79 GROUP-63 FULL ASCII TABLE ( CODE 39 ) MODIFIER KEYS $T%M $T%L Alt (Left) break $T+F Alt (Left) make*1 $T+E Alt (Right) break $T%O Alt (Right) make $T%N Shift (Left) break $T+J Shift (Left) make *2 $T+I Shift (Right) break $T+L Shift (Right) make $T+K...
  • Page 80: Trouble Shooting

    GROUP-64 TROUBLE SHOOTING Our Barcode Scanners are simple to install and use. Most operational issues can be attributed to: INCORRECT INTERFACE CONNECTION INCORRECT CONFIGURATION SETUP POOR BARCODE QUALITY GENERAL PROCEDURES First, make sure the scanner is firmly connected to the host computer, when attached correctly, the scanner will emit one long beep.
  • Page 81 GROUP-65 TROUBLE SHOOTING RS232 INTERFACE PROBLEMS Once you read bar code, there is no output on the monitor, the symptoms may be caused by: 1. Have you set the protocol of RS232 like Baud rate, data bits, parity and handshaking etc. of a scanner to match to the PC terminal setting? Solution: reset the above mentioned RS232 protocol of scanner to match to PC protocol.
  • Page 82 GROUP-66 TROUBLE SHOOTING Is the proper symbology enabled? Each bar code symbology can be individually enabled or disabled. It is suggested that you enable only those that you will be scanning, thereby eliminating the possibility of mis reads from the scanning of other symbologies. Does the selected bar code symbology con guration match the bar code(s) being read? Scanned data from each bar code symbology can be restricted...
  • Page 83: Appendix 1

    APPENDIX 1 DEFAULT TABLE 1 GROUP Computer Type PC-AT Interface (depends on customer order) Setup Code Reading Mode Trigger Bi-color Light Source Green > Red Magnetic Switch Green LED/ Supplement Light (CCD Scanner) Deactivation Time (CCD & Laser Scanner) 3 Sec Same Code Interval (Laser Scanner) 30 Sec Idle Mode...
  • Page 84: Default Table

    APPENDIX 1 DEFAULT TABLE 2 UPC-A Enable UPC-E Enable EAN-8 Enable EAN-13 Enable Disable Code 39 Enable Code 11 Disable Code 93 Disable EAN-128 Enable IATA Disable GS1 Databar Disable GS1 Databar Stacked Enable GS1 Databar Limited Disable GS1 Databar Expanded Disable GS1 Databar Expanded Stacked Enable...
  • Page 85 APPENDIX 1 DEFAULT TABLE 3 Enable/Disable Enable Check Digits Disable CDV 6 digits Min Length Max Length 48 digits ST/SP; Abcd/abcd, abcd/tn*c, ABCD/ABCD ABCD/ABCD,ABCD/TN*C Start(ST)/Stop(SP) Send CLSI Format ON/OFF Insert Data ON/OFF Insert Data ON/OFF Insert Data Adjacent Required Full ASCII 39 Enable/Disable Enable Check Digits Disable CDV...
  • Page 86: Appendix 1 Default Table

    APPENDIX 1 DEFAULT TABLE 4 Enable/Disable Enable Check Digits Send Lead Digits Send Add a space Addenda required +5 On/Off +2 On/Off ISSN On/Off ISBN Enable/Disable Enable Code ID Disable Func 1 Char Send Not Send Enable Enable/Disable Check Digits Disable CDV Min Length 5 digits...
  • Page 87: Appendix 2 Cable Pin Assignment

    APPENDIX 2 Cable Pin Assignment INTERFACES: 1. TTL, Wand Emulation 1.1 ) AMP (D-Sub 9Pin): Signal Data +5VCC 1.2 ) Din 5 male (240 degree): Signal + 5VCC Data 2. Keyboard Interface: Type of connector: 2.1 ) PS/2 Mini Din6 Female: Signal PC Data +5VCC...
  • Page 88 APPENDIX 2 Cable Pin Assignment 2. Keyboard Interface: Type of connector: 2.3) PC-AT: Din 5 Male: Signal KB-Clk KB-Data +5VCC 2.4) PC-AT: Din 5 Female: Signal PC-Clk PC-Data +5VCC 3.RS232 Interfaces: 3.1) DB9F Signal TXD(Out) RXD(In) CTS(In) RTS(Out) +5VCC 3.2) DB25F Signal RXD(In) TXD(Out)
  • Page 89: Appendix 3 Barcode Test Chart

    APPENDIX 3 BAR CODE TEST CHART NARROW WIDE CHAR.GAP DENSITY mm[mil] mm[mil] mm[mil] RATIO MEDIUM 0.25(10) 0.625(25) 0.25(10) 1/2.5 DENSITY MEDIUM DENSITY NW-7 [CODABAR] CODE-39 Interleaved 2of5...
  • Page 90 APPENDIX 3 BAR CODE TEST CHART NARROW WIDE CHAR.GAP DENSITY mm[mil] mm[mil] mm[mil] RATIO 0.33(13) 0.825(32.5) 0.33(13) 1/2.5 DENSITY LOW DENSITY...