ACTIVE CONTROL INSPECTION (ISC RPM CONTROL)
Check 1
1) Set up the SDS tool. (Refer to the SDS operation manual for
further details.)
2) Check that the engine is running.
3) Make sure that the engine temperature on data monitor is
indicated 80 °C or more.
4) Click the "Active control".
5) Click the "ISC rpm control" 1.
6) Check that the "Spec" 2 is idle speed 1 500 ± 100 rpm.
7) Check that the "Desired idle speed" 3 is within the specified
idle rpm.
Check 2
1) Click the button 1 and decrease the "Spec" 2 to 1 000 rpm
slowly.
2) Check that the "Desired idle speed" 3 is nearly equal to the
"Spec" 2. At the same time, check that the air volume of the
.
ISC duty decreases
3) Click the button 4 and increase the "Spec" 2 slowly.
4) Check that the "Desired idle speed" 3 is nearly equal to the
"Spec" 2. Also, check that the air volume 5 of the ISC duty
.
increases
RV125K7 ('07-MODEL) 73