Whirlpool ET22DKXDB00 Use And Care Manual page 15

22’ to 25’ no-frost designerstyle top freezer refrigerator
Table of Contents

Advertisement

Connecting
to water
line
1. Find a %inch to 1 X-inch vertical COLD water pipe
near the refrigerator.
NOTE: Horizontal pipe will work, but the following
precaution must be taken: Drill on the top side of
the pipe, not the bottom. This will help keep water
away from the drill. This also keeps normal sedi-
ment from collecting in the valve.
2. Measure from connection
on rear of refrigerator to
water pipe. Add 7 feet (2.1 m) to allow for moving
refrigerator for cleaning. This is the length of l/4-
inch O.D. copper tubing you will need for the job
(length from connection
to water pipe PLUS 7 feet
[2.1 ml). Be sure both ends of copper tubing are
cut square.
Vertical cold
water pipe
%-inch O.D. copper
tubing (length from
3. Turn OFF main water supply. Turn ON nearest
faucet long enough to clear line of water.
4. Using a grounded drill, drill a Winch hole on the
cold water pipe you have selected.
5. Fasten shut-off valve to cold water pipe with pipe
clamp. Be sure outlet end is solidly in the %inch
drilled hole in the water pipe and that washer is
under the pipe clamp. Tighten packing nut. Tighten
the pipe clamp screws carefully and evenly so
washer makes a watertight seal. Do not overtighten
or you may crush the copper tubing, especially if
soft (coiled) copper tubing is used. Now you are
ready to connect the copper tubing.
6. Slip compression
sleeve and compression
nut on
copper tubing as shown in diagram. Insert end of
tubing into outlet end squarely as far as it will go.
Screw compression
nut onto outlet end with
adjustable wrench. Do not overtighten.
Turn ON
main water supply and flush out tubing until water
is clear. Turn OFF shut-off valve on the water pipe.
Coil copper tubing.
TO REFRIGERATOR +
Connecting
to refrigerator
1. (On kit models, assemble water valve to refrigera-
Use only %-inch copper
tor per kii instructions.)
Route the copper tubing
tubing from cotd
through the tube clamp provided as shown at left.
water line
Connect the N-inch copper tube from the shut-off
valve to the water valve at the lower, left rear of
cabinet. Use a compression
nut and sleeve as
Tube clamp
shown at left. Tighten the compression
nut. Do
not overtighten.
00
00
2. Turn shut-off valve ON. CHECK FOR LEAKS.
00
00
'/cinch compression
TIGHTEN ANY CONNECTIONS
(INCLUDING
00
00
nut and rteeve
CONNECTIONS
AT THE VALVE) OR NUTS
00
00
THAT LEAK.
00
3. The ice maker is equipped with a built-in water
00
on
strainer. If local water conditions require periodic
cleaning or a well is your source of water supply, a
second water strainer should be installed in the
%inch water line. Obtain a water strainer from your
nearest appliance dealer. Install at either tube
connection.
4. Reconnect electrical supply to refrigerator.