Dražice OKC 80 Operating And Installation Manual page 8

Tank-type water heaters
Table of Contents

Advertisement

VOLUME
MAX OPERATING
OVERPRESSURE IN THE TANK
MAX MAXIMUM OPERATING
OVERPRESSURE IN THE
EXCHANGER*
ELECTRICAL CONNECTION
RECOMMENDED BREAKER
INPUT
EL. PROTECTION
MAX TEMPERATURE OF HOT
WATER
MAX OPERATING
TEMPERATURE IN THE
EXCHANGER
RECOMMENDED
TEMPERATURE OF HOT
WATER
HEIGHT OF THE HEATER
DIAMETER OF THE HEATER
MAX WEIGHT OF THE
HEATER WITHOUT WATER
TIME OF EL. HEATING FROM
10°C TO 60°C*
TYPE
EXCHANGER HEAT TRANSFER
SURFACE
HEATING TIME BY
EXCHANGER FROM 10°C TO
60°C AT FLOW 720 l/h
RATED THERMAL OUTPUT AT
HEATING WATER
TEMPERATURE 80°C AND
FLOW 310 l/h
HEATING TIME BY
EXCHANGER FROM 10°C TO
60°C AT FLOW 310 l/h
LOAD PROFILE
DAILY ELECTRICITY
CONSUMPTION
MIXED WATER V40
TYPE
EXCHANGER HEAT TRANSFER
SURFACE
RATED OUTPUT AT HEATING
WATER TEMPERATURE OF
80°C AND FLOW 720 L/H
HEATING TIME BY
EXCHANGER FROM 10°C TO
60°C
STATIC LOSS
Table 2
OKC 80
OKC 100
OKC 100/1 m
L
75
MPa
MPa
V
W
°C
°C
°C
mm
736
mm
524
kg
43
53/59
hrs
1,1
OKC 80
OKC 100
2
m
0,41
min
32
W
6000
9000
min
50
M
kWh
6,19
L
138,7
165,41
OKC 100/1m
2
m
-
W
-
24000
min
-
W
OKC 125
2
OKC 125/1 m
95
120
3/N/PE ~ 230V/50 Hz
881
1046
524
524
59/65
1,4
1,7
OKC 125
0,68
0,68
23
28
9000
48
55
M
M
6,31
6,59
231,1
2
OKC 125/1m
1,08
1,08
24000
14
17
47
57
OKC 160
2
2
OKC 160/1 m
147
0,6
1
3X10 A
4000
IP 44
90
110
60
1235
524
67/73
2,1
OKC 160
0,68
35
9000
67
L
12,03
242,83
2
2
OKC 160/1m
1,08
24000
21
67
- 8 -
OKC 180
OKC 180/1
175
1187
584
73/78
2,5
OKC 180
0,68
40
9000
77
XL
20,11
297,01
OKC 180/1
1,08
24000
25
70

Advertisement

Table of Contents
loading

Table of Contents